Modification of selective electrode based on magnetic molecularly imprinted polymer for bisphenol A determination
| dc.contributor.author | Piyawan Leepheng | |
| dc.contributor.author | Dalawan Limthin | |
| dc.contributor.author | Korakot Onlaor | |
| dc.contributor.author | Benchapol Tunhoo | |
| dc.contributor.author | Darinee Phromyothin | |
| dc.contributor.author | Thutiyaporn Thiwawong | |
| dc.date.accessioned | 2026-05-08T19:19:16Z | |
| dc.date.issued | 2021-3-19 | |
| dc.description.abstract | Abstract Selective electrodes were modified by using the magnetic molecularly imprinted polymer (MMIP) technique on a screen-printed electrode (SPE) to detect bisphenol A (BPA). Superparamagnetic iron oxide nanoparticles (SPIONs) greatly enhance electrochemical signals due to their superparamagnetic properties. The SPIONs are non-toxic, biocompatible and highly stable. The SPIONs, especially magnetite (Fe 3 O 4 ), were synthesized from ferrous chloride and ferric chloride using a chemical co-precipitation method. The crystalline structure of the synthesized SPIONs was obtained by X-ray diffractometer, representing cubic inverse spinel structure like magnetite. The synthesized SPIONs had particle sizes of 9.87 ± 2.67 nm, which was confirmed by transmission electron microscope. The magnetic property was measured by a vibrating sample magnetometer, which presented the saturated magnetization, magnetic remanence value and coercivity as 48.76 emu g −1 , 0.497 emu g −1 and 6.265 Oe, respectively. The surfaces of modified electrodes were characterized by a scanning electron microscope, which revealed BPA template cavities on the electrode surface. The electrochemical properties were studied by cyclic voltammetry and amperometry. The bisphenol A-magnetic molecularly imprinted polymer electrode (BPA-MMIP/SPE) has a sensitivity of 2.909 with a limit of detection of 2.053 × 10 −8 M. The concentration range for BPA detection is 2.5 × 10 −8 to 1.00 × 10 −4 M, which can be applied to detection in a real sample. | |
| dc.identifier.doi | 10.35848/1347-4065/abf079 | |
| dc.identifier.uri | https://dspace.kmitl.ac.th/handle/123456789/16902 | |
| dc.publisher | Japanese Journal of Applied Physics | |
| dc.subject | Analytical chemistry methods development | |
| dc.subject | Electrochemical Analysis and Applications | |
| dc.subject | Analytical Chemistry and Sensors | |
| dc.title | Modification of selective electrode based on magnetic molecularly imprinted polymer for bisphenol A determination | |
| dc.type | Article |