Thermal-hydraulic performance of solar receiver duct with inclined punched-ribs and grooves
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Case Studies in Thermal Engineering
Abstract
The article presents an experimental study on turbulent airflow friction and thermal behaviors in a solar receiver heat exchanger duct mounted with combined inclined chamfered-groove and turbulators. The experimental work was conducted for Reynolds numbers from 5,300 to 24,000, based on the hydraulic duct diameter. The 45°-inclined punched-ribs and grooves were placed periodically on the absorber plate. The punched-rib parameters were four inclination angles (β = 0°, 45°, 90° and 135°) of the punched holes and three relative rib pitches (PR = 1, 1.5 and 2) whereas only a rib blockage ratio (BR = 0.5) and an angle of attack (α) of 45° were fixed. Similarly, the parameters of the grooves included only three groove-pitch ratios (PR), similar to the rib pitches and one groove blockage ratio (BR = 0.2). The experimental result has revealed that the combination of rib-groove turbulators at β = 0° (solid rib) and PR = 1 gives the maximum heat transfer rate and friction loss while the greatest thermal enhancement factor of 2.1 was found at β = 45°, PR = 1. Moreover, the friction loss and heat transfer correlations for this thermal system were determined.