A simplified heat transfer model of a closed refrigerated display cabinet

dc.contributor.authorChaomuang, Nattawut
dc.contributor.authorLaguerre, Onrawee
dc.contributor.authorFlick, Denis
dc.date.accessioned2026-08-06T10:22:46Z
dc.date.available2026-08-06T10:22:46Z
dc.date.issued2019-01-01
dc.description.abstractA simplified heat transfer model for a closed refrigerated display cabinet was developed based on a zonal approach. The developed model allows the prediction of time-averaged air and load temperatures at various positions in the display cabinet. These predicted values were compared with measured air and load temperatures. Good agreement was found between them with the maximum difference of 0.5°C for every studied position and the overall mean absolute error of 0.2°C. Air and load temperatures vary with positions. High temperature was observed at the front (highest value at the front top) and low at the back (lowest value at the back bottom). Based on the simulation, the cabinet thermal performance can be enhanced by minimizing the size of door gaps.
dc.identifier.citationRefrigeration Science and Technology, 2019-August, 2879-2886, 2019
dc.identifier.doi10.18462/iir.icr.2019.0049
dc.identifier.issn01511637
dc.identifier.other2-s2.0-85082651620
dc.identifier.urihttps://dspace.kmitl.ac.th/handle/123456789/9377
dc.sourceRefrigeration Science and Technology
dc.subjectClosed refrigerated display cabinet
dc.subjectHeat transfer
dc.subjectSimplified model
dc.subjectTemperature
dc.titleA simplified heat transfer model of a closed refrigerated display cabinet
dc.typeConference Paper

Files