Heat transfer of a coil-tube heat exchanger in the freeboard zone of a rice husk fluidized-bed combustor
| dc.contributor.author | Chokphoemphun, S. | |
| dc.contributor.author | Eiamsa-ard, S. | |
| dc.contributor.author | Promvonge, P. | |
| dc.contributor.author | Thongdaeng, S. | |
| dc.contributor.author | Hongkong, S. | |
| dc.date.accessioned | 2026-08-06T10:33:45Z | |
| dc.date.available | 2026-08-06T10:33:45Z | |
| dc.date.issued | 2021-10-01 | |
| dc.description.abstract | This research presents an investigation on heat recovery from a fluidized-bed combustor by using coil-tube heat exchangers positioned inside the freeboard zone. Rice husk was used as a fuel at a constant mass flow rate of 8 kg/h. Heat recovery experiments were performed at four different air mass flow rates (6.0248, 6.8077, 7.8163, and 8.8646 kg/h) using coil-tube heat exchangers wrapped around with steel wires in three different configurations (2_Coil wires, 4_Coil wires and Full length). Air was supplied to the coil-tube heat exchanger with two different air flows corresponding to flue gas flow: co-flow and counter-flow. The results showed that the outlet temperature tended to decrease with an increase in air flow rate in the coil-tube heat exchanger. The outlet temperatures obtained from the system with co-flow were greater than the one with counter-flow by 7–17 °C (2–15%) depending on the coil-tube heat exchanger configuration. The heat transfer rates in heat recovery process were in the range of 279–425 J/s. In addition, it was found that the heat transfer rate and the outlet temperature of the air from the coil-tube heat exchanger increased with an increase in the number of coil wires wrapped around the outer surface of the coil-tube heat exchanger. | |
| dc.identifier.citation | International Communications in Heat and Mass Transfer, 127, 2021 | |
| dc.identifier.doi | 10.1016/j.icheatmasstransfer.2021.105462 | |
| dc.identifier.issn | 07351933 | |
| dc.identifier.other | 2-s2.0-85111340737 | |
| dc.identifier.uri | https://dspace.kmitl.ac.th/handle/123456789/12341 | |
| dc.source | International Communications in Heat and Mass Transfer | |
| dc.subject | Coil-tube | |
| dc.subject | Combustion | |
| dc.subject | Fluidized bed combustor | |
| dc.subject | Heat recovery | |
| dc.subject | Rice husk fuel | |
| dc.title | Heat transfer of a coil-tube heat exchanger in the freeboard zone of a rice husk fluidized-bed combustor | |
| dc.type | Article |