Thermal effectiveness and entropy-exergy estimation in a tube with punched double V-winglets
| dc.contributor.author | Jayranaiwachira, Nuthvipa | |
| dc.contributor.author | Sripattanapipat, Somchai | |
| dc.contributor.author | Promvonge, Pongjet | |
| dc.contributor.author | Erfanian Nakhchi, Mahdi | |
| dc.contributor.author | Skullong, Sompol | |
| dc.date.accessioned | 2026-08-06T10:55:48Z | |
| dc.date.available | 2026-08-06T10:55:48Z | |
| dc.date.issued | 2026-06-01 | |
| dc.description.abstract | Vortex generators are effective devices for enhancing heat transfer rates in heating or cooling systems with minimal frictional losses via the production of streamwise vortices. This research effort presents the perforated double V-winglet (P-DVW) and looks at how it affects heat transmission and friction when mounted inside a heat exchange tube that is consistently heated for producing multiple vortices whereas its flow is turbulent. Optimizing thermal performance for increased energy savings and maximizing the Nusselt number ( Nu ) to minimize heat exchanger size are the major goals. Thermal characteristics, including generated entropy and exergy efficiency, are explored in depth. A Reynolds number (Re) that varies from 4760 to 29,270 is employed to explore the friction and thermal features of the tube. The P-DVW parameters encompass attack angles of α<inf>2</inf> = 15° and α<inf>1</inf> = 30°, four porosity ratios ( A <inf>h</inf>/ A <inf>w</inf> = 0, 0.0188, 0.0523, and 0.1026), and three pitch ratios, P<inf>R</inf>, (0.75, 1, and 1.25), while maintaining a constant winglet height. At P<inf>R</inf> = 0.75 and A <inf>h</inf>/ A <inf>w</inf> = 0, the P-DVW exhibits peak f and Nu values around 23.83 and 5.31 times bigger than those of the plain tube, accordingly. Further, under the specified conditions, it yields minimal entropy production, while the optimal exergy efficiency is roughly 0.9829. The thermal effectiveness of P-DVW is anticipated to reach its maximum at 2.55 with Nu<inf>R</inf> = 4.54 at A <inf>h</inf>/ A <inf>w</inf> = 0.0523 and P<inf>R</inf> = 0.75 to reveal its actual benefits. Furthermore, the correlations of f , Nu , and TEF were determined for the examined range of values. | |
| dc.identifier.citation | International Journal of Thermal Sciences, 224, 2026 | |
| dc.identifier.doi | 10.1016/j.ijthermalsci.2026.110668 | |
| dc.identifier.issn | 12900729 | |
| dc.identifier.other | 2-s2.0-105027256465 | |
| dc.identifier.uri | https://dspace.kmitl.ac.th/handle/123456789/18179 | |
| dc.source | International Journal of Thermal Sciences | |
| dc.subject | Entropy generation | |
| dc.subject | Exergy efficiency | |
| dc.subject | Heat transfer | |
| dc.subject | Punched winglet | |
| dc.subject | Vortex generator | |
| dc.title | Thermal effectiveness and entropy-exergy estimation in a tube with punched double V-winglets | |
| dc.type | Article |