dc.description.abstractThe high penetration of wind power into interconnected power system may cause the severe problem of inter-area oscillations. To stabilize power oscillations, superconducting magnetic energy storage (SMES), which is capable of controlling active and reactive powers simultaneously, can be applied. To achieve the practical SMES controller design, this paper focuses on a robust SMES controller design based on wide-area synchronized phasor measurement units (PMUs) in an interconnected power system with wind farms. The structure of active and reactive power controllers of SMES is the first-order lead/lag compensator. Assuming that multiple PMUs are located in an interconnected power system, the steady-state phasor data are obtained by applying the small load perturbation. Using the phasor data, the simplified oscillation model (SOM) included with SMES power controllers can be identified and applied to estimate the dominant inter-area oscillation modes. In the design, unstructured system uncertainties such as various operating conditions, system parameters variation, random wind patterns, etc., are represented by the inverse additive perturbation. To enhance the system robust stability margin, the optimization of SMES control parameters is solved by genetic algorithm in the SOM. Simulation studies in the West Japan six-machine power system confirm that the robustness of the proposed SMES is much superior to that of the conventional SMES against various operating conditions. © 2010 Institute of Electrical Engineers of Japan.
dc.identifier.citationIeej Transactions on Electrical and Electronic Engineering, 5(4), 428-438, 2010
dc.identifier.doi10.1002/tee.20556
dc.identifier.issn19314973
dc.identifier.other2-s2.0-77954473736
dc.identifier.urihttps://dspace.kmitl.ac.th/handle/123456789/2921
dc.sourceIeej Transactions on Electrical and Electronic Engineering
dc.subjectInter-area oscillations
dc.subjectPower system oscillations
dc.subjectRobust control
dc.subjectSuperconducting magnetic energy storage
dc.subjectSynchronized phasor measurement units
dc.subjectSystem uncertainties
dc.subjectWide-area stability and control
dc.subjectWind farms
dc.titleWide-area robust SMES controller design using synchronized PMUS for stabilization of interconnected power system with wind farms