Silver–water nanofluid flow and convective heat transfer in a microfin tube equipped with loose-fit twisted tapes

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Abstract

Heat transfer enhancement and performance of compact heat exchangers have been extensively studied in the past century for the purpose of promoting energy efficiency. Microfin tubes in single/two/multiple-phase flow heat exchangers into which twisted tape swirl generators are installed can promote heat transfer with a moderate pressure loss penalty. This article reports on the enhanced heat transfer of silver–water nanofluids in a microfin tube into which loose-fit twisted tapes are installed in a counter-flow arrangement. The experiments were carried out using nanofluids with various silver concentrations (0.007–0.03 vol%), loose-fit twisted tapes with clearance ratios (c/D) of 0.0 (tight-fit), 0.05, 0.075 and 0.1, for a twist ratio, y/W, of 2.0. The results indicate that the heat transfer rate (Nu) and pressure drop (f) increase with a decrease in clearance ratio (c/D) and increase in silver (Ag) nanoparticle concentration. Additionally, the thermal performance factor tends to increase with the decrease in Reynolds numbers.

Description

Keywords

Friction factor, Heat transfer, Loose-fit twisted tapes, Microfin tube, Silver–water nanofluids, Thermal performance

Citation

Journal of Thermal Analysis and Calorimetry, 140(5), 2541-2554, 2020

Collections

Endorsement

Review

Supplemented By

Referenced By