Enhanced heat transfer in a heat exchanger square-duct with discrete V-finned tape inserts
| dc.contributor.author | Noothong, Watcharin | |
| dc.contributor.author | Suwannapan, Supattarachai | |
| dc.contributor.author | Thianpong, Chinaruk | |
| dc.contributor.author | Promvonge, Pongjet | |
| dc.date.accessioned | 2026-08-06T10:11:22Z | |
| dc.date.available | 2026-08-06T10:11:22Z | |
| dc.date.issued | 2015-03-01 | |
| dc.description.abstract | The article presents an experimental and numerical study on thermal performance enhancement in a constant heat-fluxed square-duct inserted diagonally with 45° discrete V-finned tapes (DFT). The experiments were carried out by varying the airflow rate through the tested square duct with DFT inserts for Reynolds number from 4000 to 25000. The effect of the DFT with V-tip pointing upstream at various relative fin heights and pitches on heat transfer and pressure drop characteristics was experimentally investigated. Both the heat transfer and pressure drop were presented in terms of Nusselt number and friction factor respectively. Several V-finned tape characteristics were introduced such as fin- to duct-height ratio or blockage ratio (R<inf>B</inf> = e/H = 0.075, 0.1, 0.15 and 0.2), fin pitch to duct height ratio (R<inf>P</inf> = P/H = 0.5, 1.0, 1.5 and 2.0) and fin attack angle, α = 45°. The experimental results reveal that the heat transfer and friction factor values with DFT inserts increase with the increment of R<inf>B</inf> but the decrease of R<inf>P</inf>. The inserted square-duct at R<inf>B</inf> = 0.2 and R<inf>P</inf> = 0.5 provides the highest heat transfer and friction factor while the one with R<inf>B</inf> = 0.1 and R<inf>P</inf> = 1.5 yields the highest thermal performance. Also, a numerical simulation was conducted to investigate the flow structure and heat transfer mechanism inside the tested duct with DFT inserts. | |
| dc.identifier.citation | Chinese Journal of Chemical Engineering, 23(3), 490-498, 2015 | |
| dc.identifier.doi | 10.1016/j.cjche.2014.05.018 | |
| dc.identifier.issn | 10049541 | |
| dc.identifier.other | 2-s2.0-84951277007 | |
| dc.identifier.uri | https://dspace.kmitl.ac.th/handle/123456789/6195 | |
| dc.source | Chinese Journal of Chemical Engineering | |
| dc.subject | Discrete V-fins | |
| dc.subject | Friction factor | |
| dc.subject | Heat exchanger | |
| dc.subject | Square duct | |
| dc.subject | Thermal enhancement | |
| dc.title | Enhanced heat transfer in a heat exchanger square-duct with discrete V-finned tape inserts | |
| dc.type | Article |
