Design and construction of a prototype saline solution resistive voltage divider

dc.contributor.authorPhoaphan, Busayapol
dc.contributor.authorPotivejkul, Siriwat
dc.contributor.authorChaisiri, Punyavee
dc.contributor.authorYutthagowith, Peerawut
dc.date.accessioned2026-08-06T10:07:08Z
dc.date.available2026-08-06T10:07:08Z
dc.date.issued2013-09-02
dc.description.abstractThis paper presents design and construction of a prototype resistive voltage measuring system composing of a saline solution divider and resistive attenuator. The structure of the developed divider is designed in form of coaxial cylinder. The system has voltage rating of 300 kV. The developed measuring system has been test according to the IEC standard composing of unit step response test, scale factor test, withstand voltage test, and short term stability test. The experimental response times of the developed voltage measuring systems without and with shielding ring are about 50 ns and 25 ns, respectively. This accomplishment will be advantage for increasing capability of HV laboratory and for researches, which are about effect of fast transient voltage in transmission and distribution systems in Thailand. © 2013 IEEE.
dc.identifier.citation2013 10th International Conference on Electrical Engineering Electronics Computer Telecommunications and Information Technology Ecti Con 2013, 2013
dc.identifier.doi10.1109/ECTICon.2013.6559580
dc.identifier.other2-s2.0-84883117950
dc.identifier.urihttps://dspace.kmitl.ac.th/handle/123456789/5009
dc.source2013 10th International Conference on Electrical Engineering Electronics Computer Telecommunications and Information Technology Ecti Con 2013
dc.subjectFast transient
dc.subjectLightning impulse voltage
dc.subjectResistive voltage divider
dc.subjectSaline solution
dc.subjectStep response
dc.titleDesign and construction of a prototype saline solution resistive voltage divider
dc.typeConference Paper

Files