Extracting the Single-Dispersion Fractional Cole–Cole Bioimpedance Model Based on Low-Pass Filter Technique
| dc.contributor.author | Pipat Prommee | |
| dc.contributor.author | Jirat Chimnoy | |
| dc.contributor.author | Natapong Wongprommoon | |
| dc.contributor.author | Khunanon Karawanich | |
| dc.date.accessioned | 2026-05-08T19:25:45Z | |
| dc.date.issued | 2025-1-1 | |
| dc.description.abstract | This paper presents a simple approach to extracting the parameters of the single-dispersion Cole-Cole bioimpedance model. The main advantage of the proposed technique is that it is low-cost but accurate in identifying the bioimpedance models. The Cole-Cole model is simplified as a fractional low-pass filter (LPF) using a few electronic components. Based on a low-component count, the circuit can be realized using only a single operational amplifier (OPAMP), two resistors, and two potentiometers (POTs). The proposed technique can achieve a minimal error compared to the theory, ensuring accuracy. The Cole-Cole model parameter values can be extracted by measuring the filter magnitude and phase responses. The LPF topology inherently provides a low-noise output signal. Experimental results using different fruits are carried out to verify the method and compared with measurements from a commercial impedance analyzer to confirm the accuracy of the results, with the maximum errors of <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">R</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub>, <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">R</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">∞</sub>, α, and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">C</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">α</sub> being 0.94%, 2.41%, 0.85%, and 1.52%, respectively. The proposed new efficient technique provides excellent results in extracting the Cole-Cole parameters and agrees with the theoretical expectations. | |
| dc.identifier.doi | 10.1109/tim.2025.3643088 | |
| dc.identifier.uri | https://dspace.kmitl.ac.th/handle/123456789/20272 | |
| dc.publisher | IEEE Transactions on Instrumentation and Measurement | |
| dc.subject | Electrical and Bioimpedance Tomography | |
| dc.subject | Body Composition Measurement Techniques | |
| dc.subject | Microfluidic and Bio-sensing Technologies | |
| dc.title | Extracting the Single-Dispersion Fractional Cole–Cole Bioimpedance Model Based on Low-Pass Filter Technique | |
| dc.type | Article |