Performance assessment of solar air heater duct roughened with perforated-winglet vortex generators
| dc.contributor.author | Koolnapadol, Narin | |
| dc.contributor.author | Promvonge, Pongjet | |
| dc.contributor.author | Skullong, Sompol | |
| dc.date.accessioned | 2026-08-06T10:15:02Z | |
| dc.date.available | 2026-08-06T10:15:02Z | |
| dc.date.issued | 2017-01-01 | |
| dc.description.abstract | An experimental study has been conducted to investigate heat transfer, friction loss and thermal performance characteristics of turbulent flow in a solar air heater channel artificially roughened on one side (absorber plate) with multiple perforated-winglet vortex generator (PWVG). Air as the working fluid enters the test duct having a uniform surface heat-flux with Reynolds number (Re) ranging from 5200 to 24,000 in the present work. Effects of four different punched hole/pore diameters of winglet (d=2 mm, 4 mm, 6 mm and 8 mm) at a single relative winglet height (RB=b/H=0.6), relative winglet pitch (RP=P/H=3) and attack angle (β= 60°) on thermal characteristics are examined. The experimental results show that the PWVG provides the drastic increase in Nusselt number (Nu) and friction factor (f) values over the flat/smooth channel. In addition, substantial increases in Nu and f values are found for the rise in hole sizes. The maximum Thermal Enhancement Factor (TEF) is found for the pore diameter of 2 mm at lower Reynolds number. The present results are also compared with the results from the typical or solid winglet, TWVG (non-punched hole of winglet). | |
| dc.identifier.citation | International Journal of Smart Grid and Clean Energy, 6(1), 31-39, 2017 | |
| dc.identifier.doi | 10.12720/sgce.6.1.31-39 | |
| dc.identifier.issn | 23154462 | |
| dc.identifier.other | 2-s2.0-85040463249 | |
| dc.identifier.uri | https://dspace.kmitl.ac.th/handle/123456789/7204 | |
| dc.source | International Journal of Smart Grid and Clean Energy | |
| dc.subject | Absorber plate | |
| dc.subject | Solar air heater | |
| dc.subject | Thermal performance | |
| dc.subject | V-baffle | |
| dc.subject | Vortex generator | |
| dc.title | Performance assessment of solar air heater duct roughened with perforated-winglet vortex generators | |
| dc.type | Article |