Analysis of interturn fault characteristics in single phase transformer using experimental setup
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
This paper aims to study characteristics of interturn fault in a single-phase transformer using an experimental setup. Conventional dry-type single-phase transformer rated of 15 kVA and voltage of 220/440 V has been used in the experiment. The winding of transformer was separated as three sub-coils and to evaluate characteristics of interturn fault, the short-circuit between the sub-coil of high voltage side has been performed as the interturn fault. The obtained results show that the behavior of the winding fault is important for developing a fault detection scheme.
Description
Keywords
Fault, Transformer, winding short circuit
Citation
19th International Conference on Electrical Machines and Systems Icems 2016, 2017