Augmented heat transfer in rectangular duct with angled Z-shaped ribs
| dc.contributor.author | Pimsarn, Monsak | |
| dc.contributor.author | Sriromreun, Parkpoom | |
| dc.contributor.author | Promvonge, Pongjet | |
| dc.date.accessioned | 2026-08-06T09:59:36Z | |
| dc.date.available | 2026-08-06T09:59:36Z | |
| dc.date.issued | 2010-01-01 | |
| dc.description.abstract | An experiment is focused on the design of the suitable ribs used for enhancing heat transfer in a rectangular duct heat exchanger by using wall heat transfer (Nusselt number), friction loss (friction factor) and thermal performance (thermal enhancement factor) data. The Z-shaped ribs were set on the rectangular duct at 30°, 45° and 60° and flat rib was set at 90° relative to the air flow direction. Reynolds numbers studied ranging from 5000 to 25,000 in the test section. The rectangular duct has aspect ratio, AR = 10 and height, H = 30 mm with the Z-rib height (e), e/H = 0.2 and the rib pitch (P), P/H = 3. The ribs were fitted in Z-shape (Z-rib) aligned in series on the whole area of the upper plate. The results of the Z-ribs show the significant increase in heat transfer rate and friction loss over the smooth channel. The 45° Z-rib provides the highest increase in the heat transfer rate and the best thermal performance. | |
| dc.identifier.citation | Proceedings of the International Conference on Energy and Sustainable Development Issues and Strategies Esd 2010, 2010 | |
| dc.identifier.doi | 10.1109/esd.2010.5598858 | |
| dc.identifier.other | 2-s2.0-78649568645 | |
| dc.identifier.uri | https://dspace.kmitl.ac.th/handle/123456789/2880 | |
| dc.source | Proceedings of the International Conference on Energy and Sustainable Development Issues and Strategies Esd 2010 | |
| dc.subject | Angle rib | |
| dc.subject | Channel flow | |
| dc.subject | Enhanced heat transfer | |
| dc.subject | Nusselt number | |
| dc.subject | Rib | |
| dc.title | Augmented heat transfer in rectangular duct with angled Z-shaped ribs | |
| dc.type | Conference Paper |