Performance Assessment of Solar Air Heater Channel with Inclined Groove Turbulators
| dc.contributor.author | Koolnapadol, N. | |
| dc.contributor.author | Promvonge, P. | |
| dc.contributor.author | Khanoknaiyakarn, C. | |
| dc.contributor.author | Promthaisong, P. | |
| dc.contributor.author | Hoonpong, P. | |
| dc.contributor.author | Chaimanatsakun, A. | |
| dc.contributor.author | Gururatana, S. | |
| dc.contributor.author | Skullong, S. | |
| dc.date.accessioned | 2026-08-06T10:51:14Z | |
| dc.date.available | 2026-08-06T10:51:14Z | |
| dc.date.issued | 2025-05-19 | |
| dc.description.abstract | An experimental investigation was carried out to explore the thermal performance and frictional loss features in a solar air heater (SAH) channel that was intentionally roughened on the absorber surface using multiple inclined groove turbulators. The working fluid, air, flows into the SAH channel, which has a consistent surface heat flux for Reynolds numbers (Re) varying between 5290 and 22,600 in the current research. Thermal characteristics at a single inclination angle (a = 45°) are investigated in this research by comparing the effects of three distinct relative groove frequencies (P/H=PR=0.8, 1.2 and 1.6) and groove depth ratios (D/H=DR=0.16, 0.24 and 0.32). The findings highlight that the employ of inclined grooves results in a noticeable rise in Nusselt number (Nu) from 1.24 to 2.82 times relative to the smooth absorber plate (smooth channel), as well as a 1.88 to 7.9 times increase in friction factor (f). The Nu and f show an increasing trend when Re increases, whereas the opposite pattern occurs as DR and PR increase. At PR = 0.8 and DR = 0.32, the inclined groove roughness has the largest thermal effectiveness factor (TEF) of around 1.64. The Nu and f correlations, which are functions of inclined groove features, have also been established. | |
| dc.identifier.citation | Journal of Research and Applications in Mechanical Engineering, 13(2), 2025 | |
| dc.identifier.doi | 10.14456/jrame.2025.16 | |
| dc.identifier.issn | 22292152 | |
| dc.identifier.other | 2-s2.0-105006750922 | |
| dc.identifier.uri | https://dspace.kmitl.ac.th/handle/123456789/17002 | |
| dc.source | Journal of Research and Applications in Mechanical Engineering | |
| dc.subject | Heat transfer | |
| dc.subject | Inclined groove | |
| dc.subject | Solar air heater | |
| dc.subject | Thermal performance | |
| dc.title | Performance Assessment of Solar Air Heater Channel with Inclined Groove Turbulators | |
| dc.type | Article |