KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1
Browse
7 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Urinary dengue NS1 detection on Au-decorated ZnO nanowire platform(2024-06-15) ;Sitthisuwannakul, Kannika ;Sukthai, Ratchanon ;Zhu, Zetao ;Nagashima, KazukiChattrairat, KunanonBiodetection for non-invasive diagnostics of fluids, especially urine, remains a challenge to scientists due to low target concentrations. And biological complexes of the detection target may contain contaminants that also interfere with any assay. Dengue non-structural 1 protein (Dengue NS1) is an important biomarker for dengue hemorrhagic fever and dengue shock syndrome. Here, we developed an Au-decorated nanowire platform and applied it with a sandwich fluorophore-linked immunosorbent well plate assay (FLISA) to detect Dengue NS1 in urine. For the platform, we fabricated zinc oxide (ZnO) nanowires to provide a high surface area and then coated them with gold nanoparticles (ZnO/Au nanowires) to simply modify the Dengue NS1 antibody and enhance the fluorescence intensity. Our platform employs a sandwich FLISA that exhibits high sensitivity, specifically detecting Dengue NS1 with a limit of detection (LOD) of 1.35 pg/mL. This LOD was 4500-fold lower than the LOD of a commercially available kit for Dengue NS1 enzyme-linked immunosorbent assay. We believe that our ZnO/Au nanowire platform has the potential to revolutionize the field of non-invasive diagnostics for dengue. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Metal Oxide Nanostructures Enhanced Microfluidic Platform for Efficient and Sensitive Immunofluorescence Detection of Dengue Virus(2023-11-01) ;Pormrungruang, Pareesa ;Phanthanawiboon, Supranee ;Jessadaluk, Sukittaya ;Larpthavee, PreedaThaosing, JiraphonRapid and sensitive detection of Dengue virus remains a critical challenge in global public health. This study presents the development and evaluation of a Zinc Oxide nanorod (ZnO NR)-surface-integrated microfluidic platform for the early detection of Dengue virus. Utilizing a seed-assisted hydrothermal synthesis method, high-purity ZnO NRs were synthesized, characterized by their hexagonal wurtzite structure and a high surface-to-volume ratio, offering abundant binding sites for bioconjugation. Further, a comparative analysis demonstrated that the ZnO NR substrate outperformed traditional bare glass substrates in functionalization efficiency with 4G2 monoclonal antibody (mAb). Subsequent optimization of the functionalization process identified 4% (3-Glycidyloxypropyl)trimethoxysilane (GPTMS) as the most effective surface modifier. The integration of this substrate within a herringbone-structured microfluidic platform resulted in a robust device for immunofluorescence detection of DENV-3. The limit of detection (LOD) for DENV-3 was observed to be as low as 3.1 × 10<sup>−4</sup> ng/mL, highlighting the remarkable sensitivity of the ZnO NR-integrated microfluidic device. This study emphasizes the potential of ZnO NRs and the developed microfluidic platform for the early detection of DENV-3, with possible expansion to other biological targets, hence paving the way for enhanced public health responses and improved disease management strategies. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Mutation detection of urinary cell-free DNA via catch-and-release isolation on nanowires for liquid biopsy(2023-08-15) ;Takahashi, Hiromi ;Yasui, Takao ;Hirano, Masaki ;Shinjo, KeikoMiyazaki, YusukeCell-free DNA (cfDNA) and extracellular vesicles (EVs) are molecular biomarkers in liquid biopsies that can be applied for cancer detection, which are known to carry information on the necessary conditions for oncogenesis and cancer cell-specific activities after oncogenesis, respectively. Analyses for both cfDNA and EVs from the same body fluid can provide insights into screening and identifying the molecular subtypes of cancer; however, a major bottleneck is the lack of efficient and standardized techniques for the isolation of cfDNA and EVs from clinical specimens. Here, we achieved catch-and-release isolation by hydrogen bond-mediated binding of cfDNA in urine to zinc oxide (ZnO) nanowires, which also capture EVs by surface charge, and subsequently we identified genetic mutations in urinary cfDNA. The binding strength of hydrogen bonds between single-crystal ZnO nanowires and DNA was found to be equal to or larger than that of conventional hydrophobic interactions, suggesting the possibility of isolating trace amounts of cfDNA. Our results demonstrated that nanowire-based cancer screening assay can screen cancer and can identify the molecular subtypes of cancer in urine from brain tumor patients through EV analysis and cfDNA mutation analysis. We anticipate our method to be a starting point for more sophisticated diagnostic models of cancer screening and identification. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Annealed zno/al2o3 core-shell nanowire as a platform to capture rna in blood plasma(2021-07-01) ;Takahashi, Hiromi ;Yasui, Takao ;Klamchuen, Annop ;Khemasiri, NarathonWuthikhun, TuksadonRNA analytical platforms gained extensive attention recently for RNA-based molecular analysis. However, the major challenge for analyzing RNAs is their low concentration in blood plasma samples, hindering the use of RNAs for diagnostics. Platforms that can enrich RNAs are essential to enhance molecular detection. Here, we developed the annealed ZnO/Al<inf>2</inf>O<inf>3</inf> core-shell nanowire device as a platform to capture RNAs. We showed that the annealed ZnO/Al<inf>2</inf>O<inf>3</inf> core-shell nanowire could capture RNAs with high efficiency compared to that of other circulating nucleic acids, including genomic DNA (gDNA) and cell-free DNA (cfDNA). Moreover, the nanowire was considered to be biocompatible with blood plasma samples due to the crystalline structure of the Al<inf>2</inf>O<inf>3</inf> shell which serves as a protective layer to prevent nanowire degradation. Our developed device has the potential to be a platform for RNA-based extraction and detection. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Microheater-integrated zinc oxide nanowire microfluidic device for hybridization-based detection of target single-stranded DNA(2021-06-18) ;Takahashi, Hiromi ;Yasui, Takao ;Kashida, Hiromu ;Makino, KokiShinjo, KeikoDetection of cell-free DNA (cfDNA) has an impact on DNA analysis in liquid biopsies. However, current strategies to detect cfDNA have limitations that should be overcome, such as having low sensitivity and requiring much time and a specialized instrument. Thus, non-invasive and rapid detection tools are needed for disease prevention and early-stage treatment. Here we developed a device having a microheater integrated with zinc oxide nanowires (microheater-ZnO-NWs) to detect target single-stranded DNAs (ssDNAs) based on DNA probe hybridization. We confirmed experimentally that our device realized in-situ annealed DNA probes by which we subsequently detected target ssDNAs. We envision that this device can be utilized for fundamental studies related to nanobiodevice-based DNA detection. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Engineering Nanowire-Mediated Cell Lysis for Microbial Cell Identification(2019-02-26) ;Yasui, Takao ;Yanagida, Takeshi ;Shimada, Taisuke ;Otsuka, KoheiTakeuchi, MasakiResearchers have demonstrated great promise for inorganic nanowire use in analyzing cells or intracellular components. Although a stealth effect of nanowires toward cell surfaces allows preservation of the living intact cells when analyzing cells, as a completely opposite approach, the applicability to analyze intracellular components through disrupting cells is also central to understanding cellular information. However, the reported lysis strategy is insufficient for microbial cell lysis due to the cell robustness and wrong approach taken so far (i.e., nanowire penetration into a cell membrane). Here we propose a nanowire-mediated lysis method for microbial cells by introducing the rupture approach initiated by cell membrane stretching; in other words, the nanowires do not penetrate the membrane, but rather they break the membrane between the nanowires. Entangling cells with the bacteria-compatible and flexible nanowires and membrane stretching of the entangled cells, induced by the shear force, play important roles for the nanowire-mediated lysis to Gram-positive and Gram-negative bacteria and yeast cells. Additionally, the nanowire-mediated lysis is readily compatible with the loop-mediated isothermal amplification (LAMP) method because the lysis is triggered by simply introducing the microbial cells. We show that an integration of the nanowire-mediated lysis with LAMP provides a means for a simple, rapid, one-step identification assay (just introducing a premixed solution into a device), resulting in visual chromatic identification of microbial cells. This approach allows researchers to develop a microfluidic analytical platform not only for microbial cell identification including drug- and heat-resistance cells but also for on-site detection without any contamination. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Unveiling massive numbers of cancer-related urinary-microRNA candidates via nanowires(2017-12-01) ;Yasui, Takao ;Yanagida, Takeshi ;Ito, Satoru ;Konakade, YukiTakeshita, DaikiAnalyzing microRNAs (miRNAs) within urine extracellular vesicles (EVs) is important for realizing miRNA-based, simple, and noninvasive early disease diagnoses and timely medical checkups. However, the inherent difficulty in collecting dilute concentrations of EVs (<0.01 volume %) from urine has hindered the development of these diagnoses and medical checkups. We propose a device composed of nanowires anchored into a microfluidic substrate. This device enables EV collections at high efficiency and in situ extractions of various miRNAs of different sequences (around 1000 types) that significantly exceed the number of species being extracted by the conventional ultracentrifugation method. The mechanical stability of nanowires anchored into substrates during buffer flow and the electrostatic collection of EVs onto the nanowires are the two key mechanisms that ensure the success of the proposed device. In addition, we use our methodology to identify urinary miRNAs that could potentially serve as biomarkers for cancer not only for urologic malignancies (bladder and prostate) but also for nonurologic ones (lung, pancreas, and liver). The present device concept will provide a foundation for work toward the long-term goal of urine-based early diagnoses and medical checkups for cancer.
