KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1
Browse
3 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Short range electromagnetic interface using 0.35 μm CMOS blocks for temperature monitoring in isolated areas(2022-11-01) ;Sotner, Roman ;Jerabek, Jan ;Polak, Ladislav ;Prokop, RomanAyten, Umut EnginIntroduction: Infra-red (IR) and visible light (VL) based systems developed for transmission of information about physical quantities (e.g. humidity, temperature) out from closed areas, cannot be effectively employed in case of specific conditions in a targeted environment (because of fog or vapor for example). Objectives: In this work, we introduce a concept of wireless short-range transmitter and receiver to sense physical quantities, for instance temperature, with slow variation. The proposed concept is able to transmit analog-based information from isolated environments (e.g. aquariums or environments for plant growing) with high immunity against vapor and fog that limits standard optical (laser, IR band) methods of communication. Methods: In this work, a new concept of short range radiofrequency (RF) communication device consisting of transmitting and receiving parts build from active devices fabricated in 0.35 μm I3T25 3.3 V CMOS process and ferrite antennas is selected. RF part uses medium-wave propagation within 10 mm distance at frequency 700 kHz. Such an approach offers minimal path loss of the radiated energy of a signal and low-gain amplification required for restoration of similar levels as available at the transmitting side. Results: The processing of base-band signals of simple (sine wave) and complex (electrocardiogram) character was verified experimentally through the system. Application example of temperature monitoring in a closed environment, based on a temperature sensor (thermistor), verifies operationability in temperature range from 10 °C up to 50 °C. Conclusion: Compared to state-of-the-art solution, the presented concept has several advantages, for instance: less complexity; using of simpler type of modulation and demodulation; lower power consumption and significantly reduced issues caused by an environment with special transmission conditions (e.g. fog and vapor). The obtained results are in good agreement with expectations. Among others, the presented system brings beneficial performances for similar applications targeting on monitoring of low-frequency or slowly varying signals. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, New pulse oximetry detection based on the light absorbance ratio as determined from amplitude modulation indexes in the time and frequency domains(2022-05-01) ;Kainan, Pattana ;Sinchai, Ananta ;Tuwanut, PanwitWardkein, ParamoteThe Pandemic COVID-19 situation, a pulse Oximetry is significant to detect a varying blood oxygen saturation of a patient who needed the device to operate with continuous, rapid, high accuracy, and immune of moving artifacts. In this article, three main schemes for low-complexity pulse oximetry detection are proposed. In the first scheme, the light absorbance ratio (R) is obtained by separating the red and infrared photoplethysmography (PPG) amplitude modulation (AM) signals from the frequency-division multiplexing (FDM) signal with two different bandpass filters (BPFs), determining the ratio of modulation index of red and infrared PPG AM signals. In the second scheme, the output PPG AM signals for the red and infrared light wavelengths from the BPFs are transformed into the frequency domain such that the AC components of both PPG AM signals are the magnitudes of the highest peaks in their respective sidebands, while the DC components are the magnitude of their carrier frequencies; then, the AC/DC ratio of the red PPG AM signal is divided by the AC/DC ratio of the infrared PPG AM signal is R. In the last scheme, the FDM signal is transformed into the frequency domain without being passed through any BPF, and R is obtained in the same way as in the same second scheme. Experimental results obtained by using the first scheme have an average error of about 0.7138%, for the second and the last scheme have an average error of about 1%, and all the methods agree with the corresponding mathematical model. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, A Photoplethysmographic Signal Isolated from an Additive Motion Artifact by Frequency Translation(2018-08-01) ;Sinchai, Sakkarin ;Kainan, Pattana ;Wardkein, ParamoteKoseeyaporn, JeerasudaAcquiring a precise percentage of oxygen saturation (SpO2) from a finger-probe pulse oximeter is dependent on both artifact-free red and infrared photoplethysmoghaphic (PPG) signals. Nonetheless, in real-life situations, these PPG signals are corrupted by a motion artifact (MA) signal that is generated from either finger or hand movement. To resolve this MA interference, the cause of the adulteration of PPG signals by the MA signal is examined. The MA signal is found to behave like an additive noise. Additionally, the frequency responses of the MA and PPG signals show that these signals are in the same frequency band. Hence, instead of direct current, a sinusoidal wave alternating current is proposed to drive an LED source in order to shift the PPG frequency band away from the MA frequency band. Experimentally, a commercial finger-probe pulse oximeter is employed. To determine the performance of the presented scheme, the resulting PPG signals are compared with those from employing the old-fashioned LED-driving method. In addition, the accuracy is verified by computing the SpO2 value. The results reveal that the proposed approach successfully retains the fundamental morphologies of the PPG structures when motion occurs. Moreover, the calculated SpO2 values from the proposed technique provide an average error of approximately 1.4%, whereas the conventional method yields a mean error approximately 4.2%.
