KMITL

Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1

Browse

Search Results

Now showing 1 - 1 of 1
  • Some of the metrics are blocked by your 
    Item type:Publication,
    A 6-bit, two-step, successive approximation logarithmic ADC for biomedical applications
    (2016-01-01)
    Sundarasaradula, Yuwadee
    ;
    Constandinou, Timothy G.
    ;
    Thanachayanont, Apinunt
    This paper presents the design and realization of a novel low-power 6-bit successive approximation logarithmic ADC for biomedical applications. A two-step successive approximation method is proposed to obtain a piecewise-linear approximation of the desired logarithmic transfer function. The proposed ADC has been designed and simulated using process parameters from a standard 0.35 μm 2P4M CMOS technology with a single 1.8 V power supply voltage. Simulation results show that, at a sampling rate of 25 kS/s, the proposed ADC consumes 4.36 μW to 14.6 μW (proportional to input amplitudes). The proposed ADC achieves 18.6 pJ/conversion-step, maximum INL of 0.45 LSB, an ENOB of 4.97-bits, and SNDR of 31.7 dB with 1 V full-scale input range.