    Measurement of sucrose concentration using Imbibition length on paper: A device for equipment-free and environmentally-friendly detection
    (2024-04-01)
    Sitanurak, Jirayu
    ;
    Kumpong, Anongnat
    ;
    Yaimai, Orawan
    ;
    Wilairat, Prapin
    ;
    The Lucas-Washburn equation is commonly used to predict the distance (L) that a liquid travels through paper. This equation establishes that L<sup>2</sup> is linear with time and inversely proportional to the viscosity of the liquid. However, there is currently no theoretical equation connecting the viscosity of a solution to its concentration. In this study, the imbibition flow of a sucrose solution was measured along the length of a horizontal strip of filter paper, featuring a printed, thermometer-shaped hydrophobic boundary. A sample (38 μL) was dispensed onto the bulb area, and the solution's flow was visually tracked using a red dye added to the sample. The imbibition length (L) was measured by a vernier caliper at 10.0 min after the sample addition. An empirical equation, based on literature values of the viscosity (η) and concentration (C) of sucrose solutions, was proposed. By integrating this empirical equation with the Lucas-Washburn equation, the following equation was derived: L = a⋅exp{-(bC + cC<sup>2</sup>)}, where ‘a’, ‘b’ and ‘c’ are parameters. This equation was fitted to the dataset of L and C, covering C values from 0 to 60 % w/w standard sucrose solutions, resulting in a coefficient of determination of 0.9987. The plot of L against C was observed to closely follow a linear line, with a fitting providing a coefficient of determination of 0.9986. The sucrose contents in samples, such as soft drinks, syrups, and sugarcanes, determined using the imbibition length method and conventional refractometry, were in statistical agreement via the paired t-test at the 95 % confidence level. This method is simple, instrument-free, requiring only a small amount of safe red food dye, and can be conducted on-site.
      1
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Simple and fast fabrication of microfluidic paper-based analytical device by contact stamping for multiple-point standard addition assay: Application to direct analysis of urinary creatinine
    (2020-04-01) ;
    Thongrod, Suthathip
    ;
    Khongkaew, Putthiporn
    ;
    Phechkrajang, Chutima Matayatsuk
    ;
    Wilairat, Prapin
    In this work, a microfluidic paper-based analytical device (μPAD) for simultaneous multiple-point standard addition assay was fabricated by rubber stamping the hydrophobic barrier pattern onto a laboratory filter paper. The μPAD has a central zone from which an applied sample flows into eight surrounding narrow channels to which had been added the standard solutions. Each channel is connected to a circular area loaded with the reagent. The opposite end of this reagent zone is connected by second narrow channel to the final circular detection zone. The μPAD was applied to the measurement of creatinine in human urine. After addition of a urine sample, the orange-colored product arising from the Jaffé reaction is formed at the eight detection zones. A digital image of the μPAD is then recorded and the ratio of the red/green (R/G) intensity obtained using the ImageJ™ program is used in the quantitation of creatinine. The normal standard addition calibration line is constructed using the intensity ratio against the added creatinine concentrations (50–1000 mg L<sup>−1</sup>). Good linearity was achieved (r<sup>2</sup> ˃ 0.99). There were no significant differences between the creatinine content using an HPLC method (paired t-test at 95% confidence, t<inf>stat</inf> = 1.78, t<inf>critical</inf> = 2.26, n = 10). The use of simultaneous multiple-point standard addition calibration allows rapid determination of creatinine in urine with elimination of matrix interference.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Microfluidic paper-based analytical device for convenient use in measurement of iodate in table salt and irrigation water
    (2020-01-01)
    Duangdeewong, Chomphunud
    ;
    Sitanurak, Jirayu
    ;
    Wilairat, Prapin
    ;
    Nacapricha, Duangjai
    ;
    We report a convenient microfluidic paper-based analytical device (µPAD) for the determination of iodate. The µPAD was fabricated using an ink-stamp with a simple circle design. Colorimetric detection of iodate employs the oxidation of hydroxylamine by the iodate to generate nitrite which reacts with the Griess reagent producing an intense magenta color. The images were recorded by a digital camera, and converted to a green scale color intensity by ImageJ. Calibration of iodate was linear in the range of 50–400 mg L<sup>−1</sup> with a detection limit of 38.1 mg L<sup>−1</sup>. With such a wide linear range, the method can be applied to various kinds of samples with the entire process completed in 50 s. Good precision of measurement was obtained (<2 %RSD). Iodate levels were determined using the µPADs in table salt and irrigation water samples. The measured concentrations of the samples correlated well with the values as found by the standard iodometric titration (no statistical difference at a 95% confidence level). The developed device is simple with easy fabrication and rapid operation. It is portable and cost-effective and therefore suitable for quality control of iodate levels in the manufacturing and agricultural industries.