KMITL
Permanent URI for this communityhttps://dspace.kmitl.ac.th/handle/123456789/1
Browse
8 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Item, Thermal performance evaluation of a channel with twisted baffles installed: Effect of twisted baffle arrangement(2026-03-01) ;Eiamsa-ard, S. ;Pingta, S. ;Phila, A. ;Woncharee, K.Chamoli, S.This research aims to introduce newly designed twisted baffle for enhancing heat transfer in solar air heater. This study examined the thermo-hydraulic performance of converging twisted baffles (C-TBs) and diverging twisted baffles (D-TBs) with different numbers of loops (n = 2, 4, 6, and 8) over a Reynolds number range (Re) of 6000–24,000. The results demonstrated that both converging twisted baffles and diverging twisted baffles significantly enhanced heat transfer compared to a smooth channel. The Nusselt number, friction factor, and thermal performance factor (TPF) increased as the number of loops decreased, attributed to stronger flow reattachment. Specifically, twisted baffles with 2, 4, 6, and 8 loops enhanced Nu by approximately 2.29–3.43, 2.02–3.05, 1.77–2.74, and 1.61–2.48 times, respectively, while the friction factor increased by 5.19–5.71, 4.61–5.01, 4.06–4.43, and 3.73–4.06 times, respectively. For a given number of loops, diverging twisted baffles consistently provided higher heat transfer enhancement than converging twisted baffles, albeit with slightly increased friction losses. Across the investigated range, the 2-loop diverging twisted baffles exhibited the best overall performance, achieving the highest Nusselt number ratio (Nu/Nu<inf>SC</inf> where Nu<inf>SC</inf> is the Nusselt number of the smooth channel) of 3.43 and a maximum thermal performance factor of 1.92 at Reynolds number of 6000, establishing it as the optimal configuration among those tested. This research contributes valuable design guidelines for selecting optimal baffle configurations, thereby supporting the development of more energy-efficient solar thermal systems. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Heat transfer performance evaluation of a solar air heater duct with multiple tapered V-baffles(2025-12-01) ;Thianpong, C. ;Kaewkosum, P. ;Woncharee, K. ;Keaitnukul, W.Maruyama, N.This report aims to study the heat transfer enhancement, pressure loss characteristics, and thermal performance of a channel equipped with multiple tapered V-shaped baffles (MTVBs). The effects of up-facing and down-facing orientations, converging (C) and diverging(D) configurations, variations in the taper ratio (e<inf>CR</inf> and e<inf>DR</inf> = 0.0 and 0.5), and Reynolds number (6000 ≤ Re ≤ 24,000) are examined. The performance of UF-C-MTVBs, DF-C-MTVBs, UF-D-MTVBs, and DF-D-MTVBs is analyzed and compared with that of the conventional transverse baffles (TBs) and MVBs (e<inf>DR</inf> = 1.0). The experimental setup maintained a constant attack angle (α) of 45°, pitch ratio (p/H) of 1.5, width-shaped ratio (W<inf>b</inf>/W) of 0.25, and blockage ratio (e/H) of 0.3. Tests were conducted at a fixed Prandtl number of 0.71, and a thermochromic liquid crystal sheet was utilized to assess the local Nusselt number distribution on the wall installed with UF-C-MTVBs, DF-C-MTVBs, UF-D-MTVBs, and DF-D-MTVBs. The results reveal that the channel with MVBs (e<inf>DR</inf> = 1.0) achieves the greatest heat transfer rate, with a Nu/Nu<inf>s</inf> ratio of up to 4.37 while a f/f<inf>s</inf> ratio reaching 48.12. In contrast, D-MTVBs at e<inf>DR</inf> = 0.0, despite having a lower Nu/Nu<inf>s</inf> ratio (maximum 3.87), attain the maximum thermal performance of 1.39 at Re = 6000, owing to their optimized design that effectively enhances heat transfer while minimizing pressure drop. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Experimental investigation and ANN prediction of heat transfer enhancement in a heat exchanger tube utilizing twin corrugated twisted tapes(2025-12-01) ;Du, Y. ;Wongcharee, K. ;Thianpong, C. ;Chuwattanakul, V.Chamoli, S.This report introduces a novel twin-corrugated twisted tape (TC-TT) insert designed to enhance heat transfer in exchanger tubes. The key innovation lies in the twin-corrugated structure, which generates a twin-swirl flow effect. The corrugated surface synergistically increases flow disturbance and expands the effective heat transfer area. The studied parameters were twist ratios (y/w = 3.0, 3.5, and 4.0) and corrugation angles (θ = 45°, 60°, 75°, and 90°) at 6,000 ≤ Re ≤ 20,000. The results show that using twin-corrugated twisted tapes increases the average Nusselt number by roughly 60–135% compared to a plain tube and by 16–35% compared to a conventional single-twisted tape, confirming the effectiveness of this structural modification. This enhancement is primarily due to the combination of double swirling-flows and enhanced effective heat transfer generated by the corrugated surface. Reducing the corrugation angle (θ) and twist ratio (y/w) led to increases in the Nusselt number (Nu), friction factor (f), and thermal performance factor (TPF). Within the studied range, the Nusselt number, friction factor, and thermal performance factor reached maximum values of 5.18, 0.153, and 1.44, respectively, at a twist ratio of 3.0, a corrugation angle of 45°, and Re = 6,000. Regression analysis was utilized to develop correlations for the Nu and f, considering the Re, Pr, y/w, and θ as influencing variables. The proposed correlations for predicting the friction factor and Nusselt number have errors within ±3% and ±2%, respectively. In addition, an artificial neural network (ANN) was developed for predicting the thermal performance values occurring below the experimental study range. The optimal state ANN model shows remarkable prediction accuracy with R<sup>2</sup> of 0.965. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Thermohydraulic performance evaluation of a heat exchanger mounted with oval inclined twisted rings(2025-03-01) ;Samruaisin, P. ;Chuwattanakul, V. ;Thapmanee, P. ;Kumar, M.Naphon, P.This research examines the effects of oval inclined twisted rings (I-TRs) on thermal performance characteristics. Heat transfer enhancement, friction factor, and thermal enhancement factor tests were conducted under uniform wall heat flux with Reynolds numbers (Re) varying from 6000 to 20,000. A systematic investigation was carried out to examine the influence of different pitch ratios (p/D) and oval-ring inclination angles (θ) on thermal enhancement factor (TEF). The experimental results reveal that the Nusselt number increases with decreasing pitch ratio (p/D) and inclination angle (θ) of the I-TRs. At p/D = 1.5, the Nusselt numbers are approximately 8.59 % to 18.78 % higher than those for I-TRs with p/D values of 2.0 and 2.5. At the smallest inclination angle, θ = 30°, the Nusselt numbers are approximately higher than those at θ = 45°, 60°, 75°, and 90° by around 1.56 %, 7.21 %, 13.74 %, and 27.14 %, respectively. At a p/D ratio of 1.5 and an inclination angle of θ = 30°, the resulting thermal enhancement factor (TEF) consistently exceeds unity across the entire Reynolds number (Re) range. In contrast, for other geometries and configurations, some TEF values fall below unity at higher Re. Within the studied range, the highest TEF of 1.12 is achieved at θ = 30°, p/D = 1.5, and Re = 6,000. The key finding suggests that the performance of the thermal system is highly dependent on both the configuration and operational conditions. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Investigation of turbulent thermal-hydraulic behaviors of a heat exchanger tube with U-cut twisted-tape(2025-03-01) ;Wongcharee, K. ;Chuwattanakul, V. ;Chamoli, S. ;Maruyama, N.Hirota, M.This study examines the influences of U-cut twisted tapes (U-TTs) on thermal-hydraulic behaviors in a circular tube with uniform heat flux. The geometric parameters studied include six U-cut ratios (s/t = 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0) and two twist ratios (y/w = 3.5 and 4.0). Experimental results revealed that their U-cut ratios highly influenced heat transfer enhancement. U-TTs with U-cut ratios (s/t) of 0.5, 1.0, 1.5, and 2.0 achieved higher Nusselt numbers than conventional twisted tapes (TTs). In contrast, U-TTs with larger U-cut ratios (s/t = 2.5 and 3.0) showed reduced Nusselt numbers. However, friction losses with all U-TTs were consistently higher than those with TTs. Due to their excellent heat transfer enhancement, U-TTs with s/t ratios of 0.5 and 1.0 exhibited significantly higher thermal performance factors (TPF) than conventional TTs. The highest TPF, 1.28, was achieved by U-TTs with an s/t ratio of 0.5 and a y/w of 3.5 at a Reynolds number of 6000. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Silver–water nanofluid flow and convective heat transfer in a microfin tube equipped with loose-fit twisted tapes(2020-06-01) ;Samruaisin, P. ;Wongcharee, K. ;Chuwattanakul, V.Eiamsa-ard, S.Heat transfer enhancement and performance of compact heat exchangers have been extensively studied in the past century for the purpose of promoting energy efficiency. Microfin tubes in single/two/multiple-phase flow heat exchangers into which twisted tape swirl generators are installed can promote heat transfer with a moderate pressure loss penalty. This article reports on the enhanced heat transfer of silver–water nanofluids in a microfin tube into which loose-fit twisted tapes are installed in a counter-flow arrangement. The experiments were carried out using nanofluids with various silver concentrations (0.007–0.03 vol%), loose-fit twisted tapes with clearance ratios (c/D) of 0.0 (tight-fit), 0.05, 0.075 and 0.1, for a twist ratio, y/W, of 2.0. The results indicate that the heat transfer rate (Nu) and pressure drop (f) increase with a decrease in clearance ratio (c/D) and increase in silver (Ag) nanoparticle concentration. Additionally, the thermal performance factor tends to increase with the decrease in Reynolds numbers. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Investigation of heat transfer enhancement by perforated helical twisted-tapes(2014-03-01) ;Nanan, K. ;Thianpong, C. ;Promvonge, P.Eiamsa-ard, S.Influence of perforated helical twisted-tapes (P-HTTs) on the heat transfer, friction loss and thermal performance characteristics under a uniform heat flux condition is reported. The P-HTTs were obtained by perforating typical helical twisted-tapes (HTTs) with a prospect to reduce the friction loss of fluid flow. The experiments were conducted using P-HTTs' three different diameter ratios (d/. w) of 0.2, 0.4 and 0.6, and three different perforation pitch ratios (s/. w) of 1, 1.5 and 2. The helical pitch ratio and twist ratio were fixed at P/. D=2 and y/. w=3. Tests were performed for Reynolds number between 6000 and 20,000. The experiments using the plain tube and the tubes with HTTs were also carried out for assessment. The experimental results reveal that the use of P-HTTs leads to the reduction of friction loss as compare to that of HTT. Heat transfer, friction loss and thermal performance factor increase as d/. w decreases and s/. w increases. For the present range, the maximum thermal performance factor of 1.28 is obtained by using the P-HTT with d/. w=0.2 and s/. w=2.0 at the Reynolds number of 6000. In addition, the empirical correlations for Nusselt number, friction factor and thermal performance factor give accurate predictions within ±. 4%, ±. 6% and ±. 3%, respectively. © 2014 Elsevier Ltd. - Some of the metrics are blocked by yourconsent settings
Item type:Item, Turbulent heat transfer enhancement in a heat exchanger using helically corrugated tube(2011-03-01) ;Pethkool, S. ;Eiamsa-ard, S. ;Kwankaomeng, S.Promvonge, P.The augmentation of convective heat transfer in a single-phase turbulent flow by using helically corrugated tubes has been experimentally investigated. Effects of pitch-to-diameter ratio (P/D<inf>H</inf>=0.18, 0.22 and 0.27) and rib-height to diameter ratio (e/D<inf>H</inf>=0.02, 0.04 and 0.06) of helically corrugated tubes on the heat transfer enhancement, isothermal friction and thermal performance factor in a concentric tube heat exchanger are examined. The experiments were conducted over a wide range of turbulent fluid flow of Reynolds number from 5500 to 60,000 by employing water as the test fluid. Experimental results show that the heat transfer and thermal performance of the corrugated tube are considerably increased compared to those of the smooth tube. The mean increase in heat transfer rate is between 123% and 232% at the test range, depending on the rib height/pitch ratios and Reynolds number while the maximum thermal performance is found to be about 2.3 for using the corrugated tube with P/D<inf>H</inf>=0.27 and e/D<inf>H</inf>=0.06 at low Reynolds number. Also, the pressure loss result reveals that the average friction factor of the corrugated tube is in a range between 1.46 and 1.93 times over the smooth tube. In addition, correlations of the Nusselt number, friction factor and thermal performance factor in terms of pitch ratio (P/D<inf>H</inf>), rib-height ratio (e/D<inf>H</inf>), Reynolds number (Re), and Prandtl number (Pr) for the corrugated tube are determined, based on the curve fitting of the experimental data. © 2010 Elsevier Ltd.