Now showing 1 - 2 of 2
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Integrating Vis-SWNIR spectrometer in a conveyor system for in-line measurement of dry matter content and soluble solids content of durian pulp
    (2021-11-01) ;
    Sharma, Sneha
    ;
    ;
    Leepaitoon, Kritsanaphon
    ;
    Chunsri, Rashphon
    The prediction of dry matter content (DMC) and soluble solids content (SSC) in durian pulp were performed using a small laboratory scale in-line visible and short wave near infrared (Vis-SWNIR) spectroscopic system. The fiber optic diode array spectrometer with a charged coupled device (CCD) detector in a wavelength range of 450−1000 nm was used for spectral data acquisition. The spectra of the sample were acquired on the moving conveyor belt in two different orientations, including scanning in the upright position of pulps collected in 2018 and the stable position by scanning on the side of the pulps collected in 2019. Partial least squares regression (PLSR) was used to establish the relationship between the spectra and observed DMC and SSC values using the different wavelength ranges, including 450−1000, 700−1000, and 800−1000 nm for the comparison. The results showed that the durian pulp should be scanned in the upright position at the center of the pulp. Moving average smoothing preprocessing combined with the standard normal variate (SNV) for DMC and multiple scatter correction (MSC) for SSC gave the best result. The suitable wavelength range for model development to predict the DMC and SSC was 700−1000 nm and 800−1000 nm, respectively. After comparing the results, the optimum model showed the coefficient of determination of calibration (R<inf>C</inf><sup>2</sup>), and prediction (R<inf>P</inf><sup>2</sup>), root mean square error of prediction (RMSEP), bias, and the ratio of performance to interquartile distance (RPIQ) of 0.88, 0.83, 4.32 %, 1.25 %, and 3.52 for DMC and 0.70, 0.70, 4.0 %, 0.4 %, and 2.2 for SSC prediction.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Non-Destructive Quality Evaluation of Tropical Fruit (Mango and Mangosteen) Purée Using Near-Infrared Spectroscopy Combined with Partial Least Squares Regression
    (2022-12-01) ;
    Sharma, Sneha
    ;
    ;
    Srisawat, Kraisuwit
    ;
    Inta, Wasan
    Mango and mangosteen are commercially important tropical fruits with a short shelf life. Fruit processing is one of the alternatives to extend the shelf life of these fruits. Purée is one of the processed products of fresh fruit. In this research, the quality of mango and mangosteen purée was analyzed. Titratable acidity (TA) and total soluble solids (TSS) were predicted using non-destructive near-infrared (NIR) spectroscopy. A partial least squares regression (PLSR) model was developed based on the NIR spectra with a wavelength ranging from 800 to 2500 nm. The PLSR model returned a coefficient of determination (r<sup>2</sup>) and a ratio of prediction to deviation (RPD) of 0.955 and 4.7 for TSS, and 0.784 and 2.2 for TA, in the mango purée. Similarly, the best model was selected for the TSS prediction in the mangosteen purée through PLSR, with an r<sup>2</sup>, a root mean square error of cross-validation (RMSECV), and RPD of 0.799, 0.3% malic acid, and 2.2, respectively. The results show the possible application of NIR spectroscopy in the product processing line, although a larger number of samples with wide variation in future studies are needed as an input to update the model, in order to obtain a more robust model.