Pongampai, Satana
Loading...
Preferred name
Pongampai, Satana
Email
satana.po@kmitl.ac.th
9 results
Now showing 1 - 9 of 9
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Continuous tremor monitoring in Parkinson's disease: A wristwatch-inspired triboelectric sensor approach(2024-12-20) ;Ukasi, Sirinya; ;Panigrahi, Basanta Kumar ;Panda, SwatiHajra, SugatoParkinson's disease (PD) prevalence is projected to reach 12 million by 2040. Wearable sensors offer a promising approach for comfortable, continuous tremor monitoring to optimize treatment strategies. Here, we present a wristwatch-like triboelectric sensor (WW-TES) inspired by automatic watches for unobtrusive PD tremor assessment. The WW-TES utilizes a free-standing design with a surface-modified polytetrafluoroethylene (PTFE) film and a stainless-steel rotor within a biocompatible polylactic acid (PLA) package. Electrode distance is optimized to maximize the output signal. We propose and discuss the WW-TES working mechanism. The final design is validated for activities of daily living (ADLs), with varying signal amplitudes corresponding to tremor severity levels (“normal” to “severe”) based on MDS-UPDRS tremor frequency. Wavelet packet transform (WPT) is employed for signal analysis during ADLs. The WW-TES demonstrates the potential for continuous tremor monitoring, offering an accurate screening of severity and comfortable, unobtrusive wearability. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Synergistic Piezo- and Triboelectricity in a Novel Triglycine Sulfate/Bacterial Cellulose/Chitosan Flexible Composite Nanogenerator(2025-08-14) ;Ukasi, Sirinya ;Saichompoo, Kittipan ;Sae-tang, Chanachot ;Pakawanit, PhakkhanananOrganic piezoelectric materials offer sustainable alternatives for mechanical energy harvesting (MEH), yet their potential remains underexplored compared to inorganic counterparts. This study pioneers the use of triglycine sulfate (TGS), a rarely studied organic piezoelectric, within a flexible three-phase composite with bacterial cellulose (BC) and chitosan (CS) for piezoelectric (PENG) and triboelectric (TENG) nanogenerators. Unlike widely researched systems, TGS's unique hybrid organic–inorganic nature is leveraged here for the first time in MEH. Optimized at a 50:50 BC:CS ratio with 40 wt.% TGS, achieves a TENG output of 141.2 V and 93.3 µA post-poling—1.8 and 2.4 fold higher than unpoled samples—driven by TGS's dipole alignment. Separately, the configuration utilizing a 5 wt.% TGS loading yields 13.7 V and 0.19 µA. Advanced characterization (ATR-FTIR, SR-XTM) and simulations (COMSOL, DFT) reveal TGS's synergy with BC/CS roughness, enhancing charge generation. Delivering 118.65 µW cm<sup>−</sup><sup>2</sup>, the TENG (from the 40 wt.% TGS poled sample) powers a digital watch, showcasing practical promise. This work not only introduces TGS as a novel MEH candidate but also provides mechanistic insights into its polarization, advancing bio-hybrid nanogenerator design. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Flexible and Self-Powered Wearable Sensors for Tremor Monitoring in Parkinson'S Disease: Recent Advances in Materials and Device Architectures(2026-01-01) ;Ukasi, Sirinya ;Hajra, Sugato ;Kim, Hoe Joon ;Sriphan, SaichonParkinson's disease (PD) is a progressive neurodegenerative disorder where tremor remains one of the most prominent and disabling motor symptoms. Traditional clinical rating scales for disease severity rely on clinician observation and patient self-report, often failing to capture the dynamic and continuous nature of tremors in daily life. This drives the development of objective monitoring technologies, such as wearable sensors, for more accurate evaluation of PD severity. However, many existing systems use rigid materials that lack the mechanical compliance and skin conformability required for stable biointegration. This review summarizes advances in flexible wearable sensors for PD tremor assessment from material innovations to a device engineering perspective, covering inertial measurement units (IMUs), electromyography (EMG), and emerging self-powered systems such as triboelectric (TENG) and piezoelectric nanogenerators (PENG). This review highlightshow functional materials, microstructural design, and device architectures govern sensing mechanisms and performance, with particular emphasis on the transition from rigid components to soft, skin-interfaced technologies. Recent patent activity reflects a shift toward multimodal, wireless, and clinically integrated platforms. Despite progress, challenges remain, including motion artifacts, durability, and limited large-scale clinical validation. Integration of flexible materials, self-powered designs, and AI-driven analytics enables continuous, personalized monitoring, moving closer to real-world clinical deployment and improved patient care. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, High-Performance Droplet-Based Triboelectric Nanogenerators: A Comparison of Device Configuration and Operating Parameters(2025-05-06) ;Chaithaweep, Kanokwan ;Pharino, Utchawadee; ;Hajra, SugatoKim, Hoe JoonDroplet-based electricity generators (DEGs) harness liquid-solid electrification to convert water droplets impacts into electrical energy. This study systematically examines how droplet height, droplet volume, flow rate, and substrate tilt angle influence DEG performance using polytetrafluoroethylene (PTFE) as a triboelectric layer and deionized water. Three electrode designs (double, top, bottom) are evaluated, revealing that the double-electrode configuration delivers the highest output. This enhanced performance arises from synergistic droplet motion, electrical double-layer formation, and charge discharge, as validated by an equivalent circuit model. By varying droplet heights from 1–20 cm, volumes of 7.7–50 µL, flow rates of 50–300 drops/min, and tilt angles of 0–90°, an optimized setup yields −70 V and 22 mA, translating to a power density of 0.28 µW cm<sup>−2</sup>. High-speed imaging correlates these outputs with droplet impact dynamics and the resulting charge transfer. Additionally, the optimized DEG can power small electronic devices, charge capacitors, and monitor artificial acid rain in real-time, displaying distinct electrical signals compared to typical rainwater. These findings underscore the potential of DEGs as renewable energy harvesters and smart environmental sensors, paving the way for advanced on-demand power generation in diverse settings. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, A highly sensitive disease pre-screening approach for glycosuria: Triboelectric sensing at the liquid-solid interface(2025-03-15) ;Pharino, Utchawadee ;Chaithaweep, Kanokwan; ;Chanlek, NarongKothan, SuchartPrescreening and disease detection offer significant benefits in the prevention of serious illnesses. Traditional screening methods for disease identification have been complex and expensive, often requiring invasive procedures, which can be both harmful and uncomfortable. To address these limitations, various non-invasive screening technologies have been developed. Among recent innovations, the liquid–solid interface concept has emerged as a promising avenue for nanogenerator applications, enabling the harvesting and sensing of liquid energy and substances. In this study, we introduce a liquid–solid interface triboelectric sensor (LS-TES) for non-invasive disease screening and sensing. The LS-TES, utilizing a double-electrode configuration, delivers an immediate electrical response upon droplet contact with the solid surface and top electrode. In the case of urine glucose monitoring, our findings demonstrate a significant reduction in electrical signals with increasing concentrations of glucose, as glucose molecules hinder electron transfer from water to the solid surface, thereby disrupting the formation of the electrical double layer at the liquid–solid interface. The sensor exhibits excellent glucose sensing performance within a concentration range of 0.2 mM to 14 mM, with a detection limit of 0.25 mM and a rapid response time of 5–10 s. The LS-TES is cost-effective, highly stable, and reusable, maintaining consistent electrical responses across ten cycles of alternating droplet measurements. This work presents a preclinical assessment approach, specifically for urine glucose monitoring, utilizing an innovative sensor based on the liquid–solid interface. The proposed concept has the potential to serve as an individual indicator for early medical symptom detection, offering relief to a large number of patients. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Design and optimization of Miura-Origami-inspired structure for high-performance self-charging hybrid nanogenerator(2023-12-01); ;Pakawanit, Phakkhananan ;Charoonsuk, Thitirat ;Hajra, SugatoKim, Hoe JoonA hybrid piezoelectric-triboelectric-electromagnetic nanogenerator (HPTENG-EMG) has been designed meticulously by focusing on material selection, structural design, and performance evaluation. The module can operate using three parts; piezoelectric, triboelectric and an electromagnetic mechanism. The hybrid concept of triboelectric and piezoelectric is achieved by fabricating triboelectric-piezoelectric composite materials working through the TENG mechanism. In the material design part, the composite film between bacterial cellulose (BC) and BaTiO<inf>3</inf> nanoparticles (BT-NPs) fabricates and optimizes its properties with a suitable number of BT-NPs. The unique Miura-Origami (MO) hexagonal multilayer shape is applied within the structural design to increase the contact surface area, which enhances the electrical output signal. The third part of the hybrid system incorporates an electromagnetic generator (EMG) by designing a structure of compact and lightweight cylindrical tubes with magnetic levitation structures. The hexagonal multilayer shape of MO composite TENG (MO-CTENG) generates an open-circuit output voltage (V<inf>OC</inf>) of ∼414 V and short-circuit output current (I<inf>SC</inf>) of ∼48.3 μA with maximum output power (P) of about ∼6.94 mW. The highest I<inf>SC</inf> value of ∼38 mA can be promoted in the optimized EMG, which is higher than the MO-CTENG by ∼786 times. The practical application of this technology is demonstrated by human shaking motion for battery charging in the wireless Global Positioning System (GPS). The maximum direct current output voltage (V<inf>DC</inf>) saturation of 30 V can be achieved within 19 s. This work provides a potential methodology for increasing electrical output performance by capturing more mechanical energy through the conjunction of three phenomena into a single device, which exhibits a promising way of addressing an energy crisis. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, A Kirigami-Engineered “Skeletal Framework” Composite for Ultralow Hysteresis and Highly Stable Strain Sensors(2025-11-24); ;Chaithaweep, Kanokwan ;Pakawanit, Phakkhananan ;Charoonsuk, ThitiratBongkarn, TheerachaiWearable strain sensors are pivotal for next-generation human–machine interfaces, yet achieving high fidelity, robustness, and sustainability in a single platform remains a significant challenge. A primary obstacle is the inherent viscoelasticity of soft materials, which leads to signal drift and hysteresis. Here, we report a highly stretchable and ultrastable strain sensor fabricated through a synergistic integration of Kirigami-based structural engineering and nanocomposite material design. By introducing titanium dioxide nanotubes (TNTs) into a bacterial cellulose (BC) matrix, we create a composite with a unique internal “skeletal framework”. This framework substantially reduces viscoelastic losses, resulting in an exceptionally low hysteresis of 0.6% and ensuring robust performance with 99.4% signal stability over >10 000 cycles. Concurrently, the Kirigami-patterned structure enhances stretchability to ∼235% while the framework amplifies sensitivity 5.8-fold. The practical viability of this high-fidelity sensor is demonstrated through the precise and repeatable control of a robotic arm, where ultralow hysteresis proves more critical than raw sensitivity. The sensor’s eco-friendly, water-based fabrication aligns high-fidelity sensing with sustainable processing, presenting a clear design paradigm for engineering reliable and eco-conscious wearable electronic devices. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Kinetic analysis of liquid–solid contact electrification: Using adsorption models as mechanistic probes for hybrid EDL behavior(2026-08-01) ;Chaithaweep, Kanokwan ;Pharino, Utchawadee; ;Sriphan, SaichonCharoonsuk, ThitiratLiquid–solid interfaces are central to technologies ranging from energy storage to triboelectric nanogenerators (TENGs). Whereas classical electric double layer (EDL) theory describes these interfaces mainly in terms of electrostatic ion adsorption, hybrid EDL concepts suggest that interfacial electron transfer may also contribute importantly to charge generation. However, the hybrid EDL model has so far been discussed primarily at a qualitative level or through complex theoretical and computational treatments, and a simple, experimentally accessible macroscopic kinetic handle that can discriminate, in operando, between adsorption‑dominated and ET‑influenced regimes remains lacking. By analyzing high-resolution charging dynamics over systematically varied H₂SO₄ and HNO₃ concentrations, a clear concentration-dependent kinetic transition is identified. At low ionic strengths, the charging process is described more effectively by pseudo-second-order (PSO) kinetics, consistent with a reaction-influenced interfacial step, whereas at higher concentrations the system becomes pseudo-first-order (PFO) dominated, consistent with transport- and ion-screening-controlled behavior. Although previous studies have provided compelling theoretical and spectroscopic evidence that interfacial electron transfer contributes to liquid–solid contact electrification in TENGs, these mechanisms have rarely been examined through such simple macroscopic kinetic formalisms. In this work, classical adsorption kinetic models are used as operational probes for distinguishing electron-transfer-influenced regimes from ion-transport-dominated regimes at PTFE/liquid interfaces. The PSO-to-PFO crossover reported here is interpreted within the hybrid EDL framework as a kinetic marker of a transition from an electron-transfer-influenced charging regime at low concentration to an ion-transport- and screening-dominated regime at high concentration, thereby demonstrating how adsorption kinetics can serve as a practical diagnostic language for liquid–solid triboelectric systems. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Acidic dynamics: Unveiling mechanistic insights for improved performance in chitosan triboelectric nanogenerators(2024-07-01) ;Charoonsuk, Thitirat ;Ukasi, Sirinya ;Mokthaisong, Panadta ;Khuntakaew, PawitaHajra, SugatoIn recent years, there has been a surge in interest surrounding the development of chitosan (CS)-based triboelectric nanogenerators (TENG) for powering attachable/portable devices. Despite numerous strategies aimed at enhancing their efficiency, the selection of acid solvent has remained largely unexplored. In this study, various acids, including acetic (CH<inf>3</inf>COOH), succinic (C<inf>4</inf>H<inf>6</inf>O<inf>4</inf>), and citric (C<inf>6</inf>H<inf>8</inf>O<inf>7</inf>) acids, were investigated for their impact on mechanical and electrical output signals. Remarkably, the choice and concentration of acid were found to significantly influence performance. Specifically, employing citric acid rendered the CS solid film more pliable and yielded the highest output signal at optimal concentration levels. Under optimized conditions, the CS-TENG exhibited an open-circuit voltage output (V<inf>OC</inf>) of 157 V and short-circuit current output (I<inf>SC</inf>) of 53 µA—more than triple that of pristine CS-TENG. Mechanistic insights into electrical generation have been elucidated, underscoring the importance of solvent selection in CS TENG fabrication. These findings underscore the potential for tailored acid solvent selection to advance specialized applications in the field.1
