Now showing 1 - 4 of 4
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Entropy generation and thermal performance of tubular heat exchanger fitted with louvered corner-curved V-baffles
    (2023-02-01) ; ; ;
    Skullong, Sompol
    The current article deals with an experimental study on entropy generation analysis and thermohydraulic performance of a uniform heat-flux tube equipped with louvered corner-curved baffle tape (LCBT). Air was drawn into the inserted tube for the Reynolds number (Re) between 4760 and 29,300. The V-shaped LCBT arranged by V-tip in downstream direction was introduced with three baffle pitch ratios (P<inf>R</inf> = 1–2) and six louver angles (θ = 0–90°) for a fixed attack angle (α) of 30° and baffle height ratio (B<inf>R</inf> = 0.25). The impacts of investigated parameters on the thermal enhancement factor (TEF), Nusselt number (Nu), friction factor (f), and total entropy generation (S˙<inf>gen</inf><sup>′</sup>) were examined. The measurements showed that the LCBT with the smallest values of P<inf>R</inf> = 1, θ = 0° give the largest Nu and f at about 4.4 and 19.2 times above the plain tube values, respectively. However, the greatest TEF around 2.23 was seen for employing the LCBT at P<inf>R</inf> = 1, θ = 45°. The entropy analysis also showed that the S˙<inf>gen</inf><sup>′</sup> is found to decline with the increment of P<inf>R</inf> and θ, whereas the minimal S˙<inf>gen</inf><sup>′</sup>is at P<inf>R</inf> = 1, θ = 0° for lower Re but at P<inf>R</inf> = 1, θ = 45° for higher Re. Furthermore, the Nu and f empirical correlations for employing LCBTs were also proposed.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Enhanced thermal effectiveness of square duct with V-type double-baffles: Numerical study
    (2024-09-01) ;
    Sripattanapipat, Somchai
    ;
    ;
    Skullong, Sompol
    ;
    Promthaisong, Pitak
    The article puts forward three-dimensional computational research on heat transmission augmentation within a square channel containing 45<sup>o</sup> V-type double-baffles positioned on the lower and top parts at regular intervals in the turbulence zone for Reynolds numbers (Re) that vary from 3000 to 20,000. The primary goal of this research is to increase the thermal effectiveness and relative Nusselt number (Nu/Nu<inf>0</inf>), in order to conserve energy and reduce the size of the heating or cooling system. The simulations utilize a finite volume approach in common with the SIMPLE algorithm, whereas the turbulent model used is the realizable k–ε. The baffles are designed to be separated vertically for reducing pressure loss. Both single V-baffles and double V-baffles have four relative pitches (PR = 0.4, 0.5, 0.6, and 1.0) and height/blockage ratios (BR = 0.05, 0.1, 0.15, and 0.2), with a fixed attack angle (α) of 45<sup>o</sup>. The computational findings show that both V-baffles are capable of producing the primary vortices, but only the double V-baffles have the ability to provide the impinging streams onto the wall, cooling the region behind the baffles. This suggests that the double V-baffles not only boost heat transmission but also reduce frictional loss. When compared to a single V-baffle, the double ones enhance heat transfer by an average of 1.04–9.94% while decreasing frictional loss by an average of 9.88–31.73%. The thermal effectiveness factor (TEF) of the double V-baffles ranges from 1.03 to 3.21, and its peak value of around 3.21 is for PR = 0.4, BR = 0.05, at lower Re.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Effect of trapezoidal louvered winglets on increased heat transfer and exergy in tubular heat exchanger
    (2024-10-01) ; ; ;
    Nakhchi, Mahdi Erfanian
    ;
    Skullong, Sompol
    The effect of inserting a trapezoidal louvered winglet tape (TLWT) into a uniformly heat-fluxed tube on its thermal effectiveness was studied experimentally. The exergy and entropy analyses for turbulent flows, as well as frictional loss and thermal features, were highlighted as key aspects of the experimental finding for the Reynolds number which measured between about 4700 and 30,000. Because fixing baffles to the curved shape of tube wall presented a challenge, the baffles were consequently positioned on double surfaces of a flat tape. Six values of the louver angle (θ<inf>1</inf> = 0°, 25°, 30°, 45°, 60°, and 90°) and three values of the relative pitch of winglet (P<inf>R</inf> = 1.0, 1.5, and 2.0) were employed in the arrangement of TLWTs, with the V-apex oriented upstream (V-up). Each of these had only a fixed height (B<inf>R</inf> = 0.25) and angle of attack (α = 30°). The winglets were utilized to induce streamwise vortices which can hinder the boundary layer formation, while the louvered openings were adopted to lessen pressure drop without significantly impacting the primary vortices. The experiment results disclosed that the smallest θ<inf>1</inf> and P<inf>R</inf> produced the largest relative friction factor (f<inf>R</inf>) and Nu<inf>R</inf>, which were about 13.57 and 4.04 times higher, while P<inf>R</inf> = 1 and θ<inf>1</inf> = 45° provide the greatest TEF of about 2.27. The greatest exergy efficiency (η<inf>Ex</inf>) resulting from the TLWT was reached at θ<inf>1</inf> = 0°, but the generation of entropy (S˙<inf>g</inf><sup>′</sup>) dropped with lowering θ<inf>1</inf> and Re. A further examination, however, showed that the best scenario with α = 60° and staggered arrays is more desirable since it yields the largest TEF of 2.45 at θ<inf>1</inf> = 45° and P<inf>R</inf> = 1. For the range of parameters under consideration, the Nu and f correlations were additionally established.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Effect of louvered curved-baffles on thermohydraulic performance in heat exchanger tube
    (2023-02-01) ; ; ;
    Promthaisong, Pitak
    ;
    Skullong, Sompol
    The paper presents an experimental study of convection enhancement in a tube heat exchanger using louvered curved-baffle (LCB) vortex generator (VG). The heat transfer and pressure loss of air as a working fluid, flowing in an isothermal-fluxed tube were measured having Reynolds numbers (Re) between 4760 and 29,300. The LCB elements were arrayed on two tape sides in a V-shape with a 30° attack angle. At a fixed baffle height, the LCB had three axial pitch ratios (PR) from 0.5 to 1.5 and six louver angles (θ) from 0° to 90°. Thermal enhancement factor (TEF), Nusselt number (Nu), and friction factor (f) are often utilized to analyze the effect of VG geometrical variables on thermohydraulic performance. The measured results demonstrated that the LCB-inserted tube has a significantly larger Nu and f than a plain tube functioning alone, and that the Nu and f tend to rise when PR and θ decline. Using the LCB increases Nu and f by approximately 2.59-4.66 and 3.8-39.37 times, respectively. The maximal TEF is achieved for the LCB at PR = 1, θ = 45° and lower Re. Empirical correlations for Nu and f were evaluated and found to fit measured data well, with discrepancies by ± 9% and ±10%, respectively.