Sokjabok, Siwakon
Loading...
Preferred name
Sokjabok, Siwakon
Alternative Name
Sokjabok, S.
Main Affiliation
Email
siwakon.so@kmitl.ac.th
3 results
Now showing 1 - 3 of 3
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Preparation and evaluation of blend polymer films for wound dressing using vancomycin-loaded polycaprolactone and carboxymethyl cellulose via crosslinking methods: Effect of mechanical strength, antibacterial activity, and cytotoxicity(2024-03-01) ;Meedecha, Paweena; ;Eawsakul, Komgrit ;Ongtanasup, TassaneeTambunlertchai, SupreedaPolycaprolactone (PCL) and carboxymethyl cellulose (CMC) are two materials with beneficial properties for wound healing applications. Here, the simple preparation of PCL/CMC polymer films via the crosslinking method was demonstrated for the first time. The polymer films represented the suitable properties of liquid absorption and tensile strength to be used as a wound dressing. The blend polymer films can also load the vancomycin, which prolongs the drug release for effectiveness against S. aureus. The trifluoroethanol showed less toxicity in comparison with other crosslinking agents. This process can also be applied further in other medical devices and wound healing applications. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, An improvement of BER using two-dimensional constrained code for array-reader-based magnetic recording(2021-05-01); ;Koonkarnkhai, Santi ;Lee, JaejinTo achieve ultra-high areal densities in future magnetic recording technologies such as bit-patterned magnetic recording (BPMR) systems, each bit-island must be closely moved. However, the reduction of bit island spacing always leads to both inter-symbol interference (ISI) and inter-track interference (ITI), which can degenerate system performance. Previously, a one-dimensional (1D) run-length limited (RLL) code was employed to efficiently avoid the ISI effect, while a two-dimensional (2D) detector is widely utilized to deal with the ITI effect as well. However, its complexity is higher than the traditional 1D detector. Therefore, to avoid the fatal data patterns that lead to severe ITI effect, we first present the application of 1D RLL code to be as the 2D modulation code in the multi-head multi-track BPMR systems. Moreover, we also present the modified 2D Viterbi detector that is designed based on our proposed encoding condition. The numbers of state and branch in the traditional trellis's structure are properly reduced according to encoding condition, thus it does not only provide a lower complexity but also operate better than the traditional 2D Viterbi detector. Results reveal that our proposed coding scheme and modified 2D Viterbi detector can efficiently protect and cope with the ITI effect. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Constrained codes in single-reader/two-track reading bit-patterned magnetic recording(2021-01-01); ;Mattayakan, M. ;Buajong, C. ;Koonkarnkhai, S.Kovintavewat, P.A reduction in track width of ultra-high density magnetic recording such as bit-patterned media recording (BPMR) results in an increase in areal density. However, the unfortunate appearance of extreme inter-symbol interference (ISI) and inter-track interference (ITI) can severely deteriorate the system performance. To deal with these problems, we propose to use a single-reader/two-track reading (SRTR) technique, where a single reader was employed to read two parallel-track at once and the bit islands were arranged in a staggered manner. Then, a received readback signal was sampled at an over-sampling rate, where an obtained data sequence can be operated using only a one-dimensional equalization and detection scheme. Moreover, we also present the simple constrained coding schemes consisting of the rate-3/5 and -4/6 constrained codes, where both are properly designed for an SRTR BPMR system by avoiding all data patterns that are more susceptible to ISI and ITI effects. Simulation results show that the severe ISI and ITI effects can be mitigated through the use of our proposed coding schemes. Consequently, the proposed systems are superior to the conventional system (without our constrained codes) at a same user density of 3.0 Tb/in2.
