Chaomuang, Nattawut
Loading...
Preferred name
Chaomuang, Nattawut
Alternative Name
Chaomuang, N.
Main Affiliation
Email
nattawut.ch@kmitl.ac.th
19 results
Now showing 1 - 10 of 19
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Storage conditions, energy consumption, and food safety implications of domestic refrigerators in Bangkok(2025-12-01); ;Potisuwan, Cheeraphat ;Duret, Steven ;Derens-Bertheau, EvelynePaviet-Salomon, YvanneDomestic refrigeration plays a critical role in food preservation and safety by maintaining optimal storage conditions for perishable items. This study investigated the temperature and humidity conditions, as well as the energy consumption, of domestic refrigerators in Bangkok. Data were collected through on-site investigations of 123 refrigerators using data loggers to record temperature, humidity, and electrical consumption over a five-day period. In addition, a predictive microbiological model was used to assess the potential for microbial growth under the investigated storage conditions, specifically of Listeria monocytogenes and lactic acid bacteria (LAB). Results indicated that although the overall mean temperatures of chilling compartments (5.0 ± 2.5 °C) were within the recommended range for domestic refrigeration, only about 30–40 % of individual refrigerators consistently maintained temperatures at or below 5 °C on the top and middle shelves throughout the five-day monitoring period, where fresh and ready-to-eat products are typically stored. Electrical consumption analysis revealed significant differences across refrigerator types; appliances with two doors and bottom freezers exhibited the highest annual electrical consumption, while single door refrigerators recorded the lowest. However, the specific energy consumption (SEC) did not differ significantly among refrigerator types. The microbial exposure assessment based on a test product highlighted that for over 50 % of refrigerators, L. monocytogenes load exceeds the regulation safety limits (> 10<sup>2</sup> CFU/g) within five days. These findings emphasize the need for improved temperature control, appliance design, and consumer education to ensure food safety and energy efficiency in domestic refrigeration. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Evaporative cooling with a wet fabric blanket for non-refrigerated horticultural produce transport: An experimental study(2024-12-01); ;Laguerre, Onrawee; ;Flick, DenisDuret, StevenDue to the high cost of mechanical refrigeration, Evaporative Cooling (EC) can be an alternative technology for small farmers in developing countries, such as Thailand. This study aimed to experimentally investigate the performance of EC using a wet fabric blanket. A real-scale cargo chamber, commonly used in Thailand, was constructed, and equipped with axial fans to simulate airflow during transportation. Two pallets of test products (hollow plastic balls) were loaded into the cargo and covered with the wet blanket. During the experiment, the inlet air velocities varied from 0.8 m s<sup>−1</sup> to 3.6 m s<sup>−1</sup> while the constant climate conditions were maintained (29–30 °C and 70–73 %RH). The air and product temperatures and air relative humidity were measured every minute for 3 h using thermocouples and hygrometers, respectively. The proposed EC method allowed the air temperature to decrease by approximately 3–4 °C. When the inlet air velocity decreased, a lower temperature reduction was observed. Simplified heat and mass transfer models were developed to interpret the load temperature evolution from the inlet to the outlet positions at different air velocities. The comparison between the measured and calculated data revealed a maximum mean relative error of 1.2 %. The quality preservation performance was also evaluated based on lettuce mass loss. Lower mass loss was observed for the product stored inside the cargo chamber (<6 %) compared to those outside (8–10 %). This study suggests the potential use of a wet blanket as an EC cooling medium for a short-distance transport to enhance the cold chain performance in Thailand. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Performance Evaluation of a Wet Medium Made of Mangosteen Peels for a Direct Evaporative Cooling System(2023-12-01); ;Nuangjamnong, ThanutThe present study aimed to investigate an alternative evaporative cooling pad material made from mangosteen peel (MP) waste. Mangosteen peels were used to fill a 150 mm thick mesh container with a packing density of 180 kg/m<sup>3</sup>. A wind tunnel was constructed and utilized to experimentally evaluate the cooling performance of this organic-waste-based pad under hot and humid conditions (31–34 °C and 55–70% RH). The performance parameters assessed included pressure drop, temperature drop, saturation effectiveness, cooling capacity, and coefficient of performance (COP). The influence of air velocity (0.7, 1.0, 1.4, and 1.8 m/s) on these parameters was also examined. The results revealed that the saturation effectiveness of the MP pad ranged from 53% to 77% within the considered air velocity range. The maximum temperature drop (4.6 °C), saturation effectiveness (77%), cooling capacity (0.6 kW), and COP (3.5) were achieved when the system operated at 1.4 m/s. A comparative study showed that, at this velocity, the MP pad provided performance nearly equivalent to that of the commercial cellulose paper pad, except for the pressure drop. This result affirms the potential of mangosteen peels as a suitable wet medium for evaporative cooling applications. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Enhancing supply chain efficiency for air transport of horticultural products by simplified heat and mass transfer modelling(2026-08-01) ;Jantapirak, Suveena ;Duret, Steven ;Laguerre, Onrawee ;Denis, AlainPaviet Salomon, YvanneMaintaining temperature and quality stability of fresh horticultural products during air transportation is challenging due to highly variable thermal environments and limited airflow inside Unit Load Device (ULD) containers. This study developed a simplified three-dimensional heat and mass transfer model to predict product temperature and moisture evolution within a ULD container under realistic operating conditions. Plaster mangoes were used to avoid the variability of the real product properties. Convective heat transfer and three-directional thermal resistances were integrated into an unsteady heat balance model while the model parameters were calibrated using Monte Carlo simulation. A complementary mass transfer model, considering the ULD container as a closed moisture domain, was implemented to estimate product mass loss. Model performance was evaluated using cooling experiments under controlled conditions and field measurements in a ULD shipment from Bangkok to Paris by air transport. Simulated air and product temperatures showed good agreement with experimental data, with RMSE values below 3.5 °C. The model successfully captured the pronounced thermal load on top-layer boxes during tarmac exposure and the faster cooling of bottom boxes through conduction with the bottom wall during flight. Predicted mass loss (1.0-1.1%) also aligned with field data (1.1-1.2%). The model provides a practical tool for assessing the effects of operational and environmental conditions on fruit quality during air transport. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Dataset of air velocity and temperature fields inside an insulated box equipped with phase change material under several operating conditions(2024-02-01) ;Leungtongkum, Tanathep ;Flick, Denis; ;Denis, AlainLaguerre, OnraweeThis article contains a description of protocol to measure air velocity field (by Particle Image Velocimetry - PIV) and temperature field (by T-type thermocouples) in an insulated box equipped with Phase Change Material (PCM) of melting point 0 °C. The influence of various conditions was studied: i) PCM position (at sidewall and at top), ii) aspect ratio of the box (height/width ∼ 1 and 1.7), iii) ambient temperature (10 °C, 20 °C and 30 °C), iv) test product initial temperature (4 °C and 10 °C) and vi) spacing beneath the load (0 mm and 20 mm). This article is related to a published research paper, it provides the dataset of all experiments which can be useful for experimenter to understand the phenomena and for expert in numerical model to validate the developed model e.g., by Computational Fluid Dynamic. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Dataset of experimental study investigation of airflow and heat transfer in an insulated box equipped with a phase change material(2022-12-01) ;Leungtongkum, Tanathep ;Laguerre, Onrawee ;Flick, Denis ;Denis, AlainDuret, StevenThis article contains a detailed description of the experimental protocol of air velocity (by particle image velocimetry - PIV) and temperature measurement (by T-type thermocouples) in an insulated box equipped with a Phase Change Material (PCM). The study was conducted in an empty box and a loaded box with extruded polystyrene slabs (XPS) and methylcellulose slabs (test product). The measurement was conducted at the middle plane and lateral plane. This article contains a complete dataset along with the illustrated figures of conducted experiment. They lead to more understanding of phenomena inside a closed cavity with a cold source and can be useful for validating numerical models, e.g., the results computed by computational fluid dynamic. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, A simplified heat transfer model of a closed refrigerated display cabinet(2020-06-01); ;Laguerre, OnraweeFlick, DenisInstallation of doors on open refrigerated display cabinets is one of the simple and effective methods to improve the cabinet performance because it can reduce the warm and humid air infiltration into the cabinets. However, the presence of doors can change airflow pattern, which in turn influences the heat transfer and product temperatures. It is, thus, necessary to understand these thermal phenomena. This study proposes a simplified heat transfer model developed based on a zonal approach to describe the evolution of air and product temperatures at different zones in the closed refrigerated display cabinet. For model validation, the predicted values were compared with measured air and load temperatures for three external air temperatures. Good agreement was found between the predicted and measured temperatures with the maximum difference of less than 0.5 °C for every studied position and the overall mean absolute error of 0.2 °C. The model was then used to predict the effect of the air infiltration through the door gaps on the performance of the closed display cabinet in both thermal and energy aspects. This developed model will be further used in the modeling of the cold chain, where several types of refrigeration equipment are used to keep products under low-temperature conditions from production to consumption. Through integration of quality and microbiological predictive models, this approach can be used as a numerical tool for an evaluation tool for consumer risk. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Energy consumption and temperature performance of cold stores in food industries in Thailand(2024-05-17) ;Nuangjamnong, T.; Ongkunaruk, P.Refrigeration is an important part of the food supply chain because low temperature environment helps to maintain the quality of perishable products, thus prolonging their shelf life. However, the refrigeration system requires a considerable amount of energy consumption. This fact contributes to an increased cost in electricity bills and a reduction of competitiveness in markets. The current status of the energy consumption performance of cold stores in food companies in Thailand is scarcely available. The company stakeholders usually have no tool to evaluate their cold stores and cannot implement energy-efficiency measures effectively. In this study, a simple model based on thermal loads was developed and used to estimate the energy consumption of seven cold stores. On-site investigations were also conducted to assess their temperature performance. The results showed that the energy consumption of all investigated cold stores appeared to be better than both international and national average practices. Conversely, most cold stores exhibited moderate temperature performance. A case study of one cold store was conducted to improve its energy performance. Energy savings of 20% can be achieved by either precooling product prior to storage or using new curtain strips. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Dataset of air cargo supply chain conditions and fruit quality evolution: Case study of mango shipment from Thailand to France(2025-08-01) ;Paviet-Salomon, Y. ;Laguerre, O. ;Duret, S. ;Denis, A.Mawilai, P.This study presents a detailed dataset collected during the international transport of mangoes (Mangifera indica L. cv. ‘Nam Dok Mai Si-Thong’) within a fully loaded Unit Load Device (ULD). The ULD contained 148 boxes (14 mangoes/box) and 31 boxes were instrumented by data loggers to monitor air and mango temperatures, as well as air humidity along the shipment. Measurements were recorded every 5 min throughout the 86.2 hour journey from Bangkok (Thailand) to Paris (France), it included cold storage, refrigerated transport, airport warehouse, air transport, and final delivery to the FRISE-INRAE laboratory in Paris suburban. At reception (Day 3), all boxes were stored at two temperatures (16 °C and 21 °C) over 15 days during which mango quality was assessed. Key quality attributes such as mass loss, peel color, pH, sugar content, and visual appearance were evaluated at Day 3, Day 6, Day 9, and Day 15 to highlight the impact of storage conditions on fruit quality. It is to be noticed that the same quality assessment was undertaken after harvest and before the cold storage in Thailand (Day 0). The dataset comprises raw and processed data files that include the temperature and humidity changes over time, as well as the quality evolution. These data are stored in series of txt files, with raw values and processed results i.e. min, max, average values, standard deviation and variance to facilitate future analysis. Additionally, the dataset includes series of jpeg files of mango images at different assessment days. This dataset is valuable for both practical and research purposes. For fruit exporters, it offers the insights into how different positions within a ULD can affect mango quality during a long-distance transport and implements certain measures to minimize quality degradation. For researchers, the dataset provides a base for numerical models validation, such as simplified thermal models and Computational Fluid Dynamics simulations. The international supply chain dataset is rare because of the complexity and the cost of implementation. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Experimental and numerical characterization of airflow in a closed refrigerated display cabinet using PIV and CFD techniques(2020-03-01); ;Flick, Denis ;Denis, AlainLaguerre, OnraweeAir velocity measurements were carried out using the Particle Image Velocimetry (PIV) technique in a display cabinet under two configurations: closed and open doors. Two conditions (refrigeration system turned “on” and turned “off”) were studied in the closed configuration. The airflow pattern was almost the same for both conditions. The air curtain was quite stable. In the upper part of the cabinet, air recirculation occurred, and this phenomenon induces external air infiltration through the door gaps. The air curtain in the open configuration (refrigeration system turned “off”) was less stable than the closed configuration. Large unsteady eddies developed in the mixing layers, thereby promoting greater external air infiltration. A two-dimensional computational fluid dynamic (2D-CFD) model was developed and showed the ability to reproduce the main flow phenomena observed in the experiment. The trend of predicted product temperature profile was also in agreement with the experimental values, despite slight underestimation.