Item type:Publication, Robust power oscillation damper design for DFIG-based wind turbine(2013-09-02); ; Nakawiro, WorawatA new robust power oscillation damper (POD) design for a doubly fed induction generator based- wind turbine is proposed in this paper. The POD structure is specified by the second-order lead/lag compensator with single input signal. The parameters optimization of POD is formulated based on a mixed H<inf>2</inf>/H<inf>∞</inf> control using linear matrix inequalities. The POD parameters are optimized by the firefly algorithm so that the damping performance against system disturbances and the robustness under system uncertainties are satisfied. Simulation results in a single machine infinite bus confirm the superior robustness of the proposed POD over the conventional POD. © 2013 IEEE. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Wide area robust centralized power oscillation dampers design for DFIG-based wind turbines(2014-02-10); Inter-area oscillations are associated with machines in one part of the system oscillating against machines in other parts of the system. They are caused by two or more groups of machines that are interconnected by weak ties. To damp out the inter-area oscillations, this paper proposes the new application of wide area stability control for robust centralized power oscillation dampers (PODs) design of doubly-fed induction generator (DFIG) wind turbines. The POD with 2<sup>nd</sup>-order lead/lag compensator structure for each DFIG wind turbine is located at the control center. To stabilize the target inter-area mode effectively, the geometric measures of controllability and observability are used to choose the suitable DFIG wind turbine for stabilizing the target oscillation mode, the proper input signal of POD, and the location of phasor measurement units (PMUs). The input signal of each POD is obtained from PMU while the output signal is transmitted to the rotor side converter voltage controller of DFIG. As a result, the reactive power output of DFIG can be modulated to damp out inter-area oscillations. In the POD parameters optimization, the wide range of power output levels of DFIGs and synchronous generators, time delays due to wide area communication, and unstructured system uncertainties model are taken into account so that the damping of inter-area modes and the system robust stability margin against uncertainties can be guaranteed. Solving the problem by the firefly algorithm automatically, the optimal parameters of PODs can be achieved. The stabilizing performance and robustness of the proposed robust centralized POD are evaluated in the IEEE New England 39 bus system by eigenvalue analyses and nonlinear simulation in scenarios with severe short circuits, N-1 outage contingencies, heavy power flows, and line tripping. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Adaptive signal selection of wide-area damping controllers under various operating conditions(2018-02-01); Since operating conditions of power systems always change, the input and output signals of wide-area damping controller (WADC), which are selected at an operating point, may not be able to guarantee the damping effect at other operating points. This paper focuses on a new adaptive signal selection for WADC against several operating conditions, such as various load demands, control signal failure, line and generator outages, and effect of communication latency. The joint controllability and observability is used to determine the best input and output pairs of WADC at any operating points. Small-signal and transient stabilities study in the IEEE 50-machine system including renewable sources, i.e., wind and solar photovoltaic generators are conducted to evaluate the effect of the proposed method. Study result demonstrates that the WADC with the adaptive signal selection yields superior damping effect to the WADC with the fixed signal selection over wide range operations. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Forced Oscillation Detection Amid Communication Uncertainties(2021-09-01); ;Shah, Rakibuzzaman ;Nadarajah, Mithulananthan ;Muyeen, S. M.Emami, KianoushThis article proposes a novel technique for the detection of forced oscillation (FO) in a power system with the uncertainty in the measured signals. The impacts of communication uncertainties on measured signals are theoretically investigated based on the mathematical models developed in this article. A data recovery method is proposed and applied to reconstruct the signal under the effects of communication losses. The proposed FO detection with communication uncertainties is evaluated in the modified 14-machine Southeast Australian power system. A rigorous comparative analysis is made to validate the effectiveness of the proposed data recovery and FO detection methods. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Hierarchical Co-Ordinated Wide Area and Local Controls of DFIG Wind Turbine and PSS for Robust Power Oscillation Damping(2016-07-01); In this paper, the two-level hierarchical scheme, which consists of wide area centralized and local controls of the power oscillation damper (POD) installed with the doubly-fed induction generator (DFIG) wind turbine and the power system stabilizer (PSS) has been proposed for robust power oscillation damping. In the wide area level, the centralized POD and PSS has received the input signals from synchronized phasor measurement units (PMUs). The geometric measures of controllability and observability have been applied to select the suitable DFIG and synchronous generator (SG) for stabilizing the target oscillation modes, the proper input signals of the centralized POD and PSS, and the location of PMUs. In the local level, the suitable DFIG and SG have been equipped with POD and PSS, respectively. In the parameters optimization of POD and PSS, the practical issues such as damping performance, controller structure, communication latency, and robustness against system uncertainties have been considered. The controller efficiency and resiliency of the proposed controller have been evaluated in comparison with other controllers by eigenvalue analysis and nonlinear simulation for a wide range of operating conditions, line outage contingencies, severe faults, and communication failure. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Robust stabilization of multimachine power system by DFIG wind turbine equipped with power oscillation damper(2014-10-15); Various system uncertainties and disturbances may cause the power system instability. The power system stabilizing controller designed without taking such uncertainties into account may not tolerate and fail to operate. This paper aim at the new robust control design of power oscillation damper (POD) equipped with the doubly-fed induction generator (DFIG) wind turbine. Without difficulty of mathematic modeling, the inverse output multiplicative perturbation is used to represent system uncertainties. The structure of POD is specified as a practical 2nd-order lead/lag compensator with single input. The POD parameters optimization problem is formulated considering the variation of tie-line power flows. The POD parameters are automatically tuned by firefly algorithm so that the damping performance and robustness can be achieved. Simulation results in IEEE 9 bus test system ensure that the proposed robust POD is superior to the conventional POD in terms of the damping performance and robustness. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Coordinated DFIG Wind Turbines and Solar PV Generators for Inter-area Oscillation Damping(2018-10-22); Intermittent power injection from renewable energy sources such as wind and solar farms may cause low damping of critical inter-area oscillation modes. However, such renewable sources may be located in some areas with higher controllability of inter-area oscillations than the conventional synchronous generators. By controlling the reactive power output of such renewable sources, the superior damping effect of inter-area oscillations can be anticipated. This paper proposes the robust control design of power oscillation dampers of wind turbines with doubly-fed induction generator and solar photovoltaic generators to damp inter-area oscillations in large-scale power systems. The coordinated robust controllers are designed to achieve the desired damping and robustly operate against system uncertainties such as noises, external disturbance, and intermittent power. Study results indicate that the damping effect of coordinated wind and solar farms is higher than that of conventional power system stabilizers under various operating conditions. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Enhanced robust frequency stabilization of a microgrid against simultaneous cyber-attacks(2024-03-01) ;Kerdphol, Thongchart; A microgrid (MG) is a smart grid cyber-physical system, with component coordination relying on cyber resilience. Weak communications, protocols, and tools make the MG's secondary frequency control vulnerable to various cyber-attacks, posing new challenges and stability risks. In response to this challenge, this paper introduces the enhanced robust H<inf>∞</inf> technique considering the dynamic impacts of cyber-attacks on secondary frequency control to develop a secondary frequency control loop, improving the regulation performance and cyber resiliency of the MG frequency. The secondary control cyber-attack strategies mainly rely on false data injection (FDI), denial of service (DoS), and controller hijacking. These attack techniques are simultaneously considered in formulating the H∞ problem and control synthesis as unstructured parametric uncertainty, attenuating the concurrent cyber impacts. The study extends a load frequency control model to illustrate how cyber-attacks can be represented mathematically and physically in the MG. The results reveal that cyber-attacks affect secondary frequency control elements differently depending on the type of cyber threats used. By implementing an enhanced H∞ controller, the MG can effectively maintain stable frequency levels even when faced with malicious attacks and disruptions caused by renewable energy sources and loads. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Small-Signal Stability Enhancement Through Integration of Distributed Grid-Forming Loads Considering Multi-Agent Collaboration(2025-01-01); ; Mitani, YasunoriThe integration of distributed controllable loads in future islanding microgrids (MGs) is growing. This creates new opportunities to actively shape grid frequency and voltage. As a result, it leads to the development of distributed grid-forming loads (DGFM-Ls). Simultaneously, it is equally crucial to ensure robustness, particularly in preserving small-signal stability amid the multi-agent collaboration. This paper presents a strategy for the small-signal stability enhancement in islanding MGs with DGFM-Ls. The small-signal models of the MG with DGFM-Ls are mathematically developed and analyzed. The multi-agent cooperation is modelled to improve the small-signal stability of the MG with DGFM-Ls. Additionally, uncertainties from multi-agent cooperation, such as partial or complete lack of measured signal observability, are considered. Data quality issues are also taken into account under various conditions. Simulation results are conducted in a MG with a significant penetration of inverter-based resources under various MG operating points and conditions such as topology changes and unavailability of certain agents. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Synthetic Inertia-Power Sharing in High Renewable Power Grids Through Vehicle-to-Grid Topology(2024-01-01) ;Kerdphol, Thongchart; With the increasing integration of renewable energy sources (RESs), the overall inertia of the power system is expected to decline. The remaining inertia is crucial for regulating system frequency and mitigating excessive rates of change. The deployment of dispatchable loads, such as electric vehicles (EVs), offers a promising solution. This paper presents a synchronized inertia support framework utilizing a vehicle-to-grid (V2G) system through its bidirectional chargers. This concept is realized by integrating a large-scale energy storage system (ESS) composed of controllable EVs into an enhanced inertia emulation structure. The synthetic inertia control strategy has been refined to account for EV user convenience and synchronized state of charge (SOC) management, facilitating synchronized inertia power sharing. This approach enhances the grid's dynamic performance and resilience. Simulation results demonstrate that the proposed method effectively delivers rapid inertia support from the onboard ESS of EVs, improving frequency stability.