Keonil, Nuchnapang
Loading...
Preferred name
Keonil, Nuchnapang
Main Affiliation
Email
nuchnapang.ke@kmitl.ac.th
3 results
Now showing 1 - 3 of 3
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, The manipulation of architectural elements to achieve interior thermal comfort: A case of residential buildings in Bangkok(2013-01-01); Sahachaisaeree, NopadonThe application of combined remedial methods that enhances energy efficiency for cooling of buildings depends on efficient interactive effects to provide occupants with optimal living comfort. This paper aims to utilize small-detached houses in Bangkok to examine the best manipulation of architectural elements that can supply appropriate thermal environment in a Thai residential context, and proposes guidelines for passive design. Environmental factors such as temperature and air movement in a tropical climate were tested using computer modelling. Study results potentially propose the guideline for the architectural design process as well as recommend an interior environmental management model for post-occupancy indoor thermal improvement. The findings indicate that the proportion of a sub-division of internal space and open utility spaces are crucial ventilation factors to reduce thermal inertia for building cooling. Additionally, the results point to two critical wind speeds and the best type of voids that respond to wind direction. © Common Ground, Nuchnapang Keonil, Nopadol Sahachaisaeree, All Rights Reserved. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Energy-efficient management modeling towards interior thermal comfort: An architectural element manipulating case study on small detached houses in Bangkok(2010-01-01); Sahachaisaeree, NopadonThis paper investigates the thermal perceptual aspect from daily activities. The research uses the cases of small detached houses in Bangkok to examine the best manipulation of architectural elements to optimally provide thermal comfort in the Thai living context applying a multi-facet research methodology. Two aspects of design manipulation - the spatial arrangements and buildings feature - are examined towards the optimization modeling. The level of perceived comfort obtained from data analysis is used as input in the modeling program to be tested to obtain the model of comfort optimization strategy and to set the guideline of passive design for tropical climate. © 2010 Elsevier Ltd. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Energy-efficient management modelling towards interior thermal comfort: A case of composite dwelling features manipulation in Bangkok(2011-12-01); Sahachaisaeree, NopadonApplicability of combined remedial methods for passive cooling depends much upon the most efficient interaction effect among them to provide occupants an optimal living thermal comfort. This research thus aims to utilize the small detached house in Bangkok as a case study to examine the best manipulation of architectural elements to provide an optimal thermal comfort in the Thai living context, and to propose a guideline for thermal comfort design. Information regarding microclimate of Bangkok Metropolis is retrieved from the meteorology office to be utilized as ambient input in the computer modelling. Several design factors - temperature, humidity, and air movement - are then tested to obtain the final model of comfort optimization strategy. Test result indicates that the best type of voids responding to the 90° wind direction is large openings with relatively smaller intake, which configuration is able to increase the interior wind speed up to 1.05 m/s. The optimal type of opening for diagonal wind direction, however, has been the medium size opening with zigzag interior void, which could obtain the interior wind velocity up to 1.5 m/s. The effective range of summer day-time temperature for passive cooling in Bangkok is limited to only 30 - 33°C.