  4. Turbulent heat transfer through a heat exchanger with porous twisted tape inserts
Loading...
Thumbnail Image

Turbulent heat transfer through a heat exchanger with porous twisted tape inserts

Author(s)
Eiamsa-Ard, S.
Wongcharee, K.
Rattanawong, S.
Eiamsa-Ard, P.
Pimsarn, M.
Thianpong, C.
Date Issued
January 1, 2009
Type
Conference Paper
Abstract
In this present work, the influences of the porous twisted tape (PT) on the heat transfer and the pressure loss are studied experimentally. The comparative experiments are conducted in the tube fitted with the PT or typical twisted tape (TT) at different twist ratios, y/w = 4.0 and 5.0, in the Reynolds number ranging from 4800 to 16,000 under uniform heat flux conditions. In the experiments, the PT inserts generate swirls that modify the near wall velocity profile resulted in improvement of the heat transfer rate. The experimental results reveal that the heat transfer rates increase with decreasing twist ratio (y/w) for all twisted tapes used in the experiments. The heat transfer rates increase up to 71% with the help of the PT. The increases in average Nusselt numbers of using PT and TT are found to be 48% and 22%, respectively, over those of the corresponding plain tube. However, PT causes a considerable increase in friction factor. The mean increases of friction factors for PT and TT are respectively, about 3.14 and 2.45 times in comparison with that for the plain tube. Mean friction factor and Nusselt number for PT, are respectively 28% and 21% higher than those for TT. In addition, the empirical correlations of the Nusselt number and friction factor are also reported.
Citation
Proceeding of International Conference on Power Engineering Icope 2009, 2009
Subjects

Heat transfer

Pressure loss

Swirl flow

Turbulence flow

Twisted tape

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback