Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Design and analysis of coupling device in partial discharge detection
Loading...
Thumbnail Image

Design and analysis of coupling device in partial discharge detection

Author(s)
Marukatat, Nattapon
Kunakorn, Anantawat
Yutthagowith, Peerawut
Pumyoy, Suparat
Date Issued
October 27, 2017
Type
Conference Paper
DOI
10.23919/iseim.2017.8088766
Abstract
This paper presents design and analysis of a coupling device which is used for measurement of PD signal and AC voltage as the conventional partial discharge testing according to IEC 60270. The remarkable feature of the developed coupling device is the accuracy in PD signal measuring and the ability in eliminating noise signal Therefore, In the AC signal measuring part, the proper impedance was chosen to achieve appropriate voltage divide ratio and accuracy in PD signal measuring. In PD signal measuring part, the value of the components must be chosen properly to achieve the determined Upper and Lower limit frequency. In this part, noise signal elimination must be considered to gain less effect to PD signal, otherwise the PD signal waveform will distort. From intensive study, three different coupling device circuits were designed and constructed. The circuit of the first and second coupling device are collected from literatures. It is found that the PD signal was interfered by the testing AC voltage signal. Therefore, the last one was developed to overcome this problem. The last developed coupling device has the lower and the upper cut off frequencies of 30 kHz and 20 MHz, respectively. The results of the three coupling devices are compared to that of the commercial coupling device in the HV laboratory of King Mongkut's Institute of Technology Ladkrabang. The developed coupling devices can be used in conventional PD testing according to IEC 60270. The comparisons of the simulated and experimental results show that the performance of the developed coupling devices as same as the commercial one.
Citation
Proceedings of the International Symposium on Electrical Insulating Materials, 1, 386-389, 2017
Subjects

Coupling device

IEC 60270

Measuring impedance

Partial discharge det...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback