Thermal performance in solar air heater channel with combined wavy-groove and perforated-delta wing vortex generators

Author(s)
Skullong, Sompol
Promvonge, Pongjet
Thianpong, Chinaruk
Pimsarn, Monsak
Date Issued
May 5, 2016
Type
Article
DOI
10.1016/j.applthermaleng.2016.01.107
Abstract
An experimental investigation on thermal performance improvement in a solar air heater channel with combined wavy-groove and delta-wing vortex generator (WVG) placed on the absorber plate having a uniform wall heat-flux is carried out. The Reynolds number based on the hydraulic diameter of the channel ranges from 4800 to 23,000. The effect of the combined groove and WVG on the heat transfer and pressure drop in the channel in terms of respective Nusselt number and friction factor is examined. Investigated parameters of the WVG mounted on the grooved absorber are three wing porosity area ratios (called porosity ratio, Ah/Aw = 0.031, 0.085 and 0.167) and four groove-wing distance to channel-height ratios (g/H = 0.4, 0.5, 0.75 and 1) at a single attack angle (α = 45°). The experimental result reveals that at g/H = 0.5, the smaller Ah/Aw provides the highest Nusselt number and friction factor around 6 and 30 times over the smooth channel, respectively, but the optimum thermal performance is at Ah/Aw = 0.085 and g/H = 0.5. The combined devices give the thermal performance augmentation at about 37.7-46.3% higher than the groove alone and also at about 1.5-12.5% above the combined groove and non-perforated WVG (without hole).
Citation
Applied Thermal Engineering, 100, 611-620, 2016
Subjects

Delta-wing

Solar air heater

Thermal performance

Vortex generators

Wavy-groove

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback