Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Accurate Loss Tangent Determination in Damped Alternating Voltage Tests
Loading...
Thumbnail Image

Accurate Loss Tangent Determination in Damped Alternating Voltage Tests

Author(s)
Yutthagowith, Peerawut
Chaisiri, Punyavee
Paophan, Busayapol
Date Issued
January 1, 2024
Type
Conference Paper
DOI
10.1109/ICPSAsia61913.2024.10761371
Abstract
Underground cables are crucial for sustainable energy systems due to their minimal visual impact, reliability, and resilience against weather-related disruptions. As reliance on renewable energy sources rises, their importance grows. Regular evaluation of these cables is essential for ensuring safety, reliability, and resilience of electricity networks. By promptly identifying risks like insulation degradation, utilities can optimize maintenance, prioritize repairs, and bolster the integration of renewables, enhancing overall infrastructure performance. Loss tangent is the most significant value used for evaluation of the cable condition. This paper presents an alternative method for estimation of loss tangent in comparison with a conventional approach in damped alternating current voltage (DACV) tests. In the loss tangent estimation, the equivalent circuit of the DACV test system and a damping factor of the measured test voltage are utilized in the loss tangent estimation. From simulation experimental results, it is found that the conventional method is not accurate in loss tangent estimation in cases of low loss tangent measurement in the range of 0.1% which is a typical value of the new and used underground power cables. However, the accuracy of the proposed method is still in the acceptable range for estimation of the loss tangent in the range of 0.1%
Citation
2024 IEEE IAS Industrial and Commercial Power System Asia I and Cps Asia 2024, 33-37, 2024
Subjects

damped alternating vo...

equivalent circuit

loss tangent

on-site tests

underground power cab...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback