Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Finite element analyses for a study of hepatic cancer tissue destruction using monopolar and bipolar radio-frequency ablation
Loading...
Thumbnail Image

Finite element analyses for a study of hepatic cancer tissue destruction using monopolar and bipolar radio-frequency ablation

Author(s)
Tungjitkusolmun, S.
Boontaram, A.
Lertprasert, P.
Krairiksh, M.
Date Issued
November 28, 2005
Type
Conference Paper
Abstract
This paper presents three-dimensional finite element analyses of radio-frequency hepatic tumor ablation. The analyses performed in this paper are composed of two systems. In the first system, the simulation was of monopolar ablation (one needle), while the second system was the simulation of bipolar ablation (two needles). We performed a preliminary study of thermal and electrical distributions of both systems. Additional simulations of bipolar ablation were performed to investigate the effect of spacing distance between two needle electrodes (2 cm, 3 cm, 4 cm, and 5 cm). The ablation duration used in all cases was 10 min, and the controlled maximum temperature was set to 90°C. From the results, the electric field in monopolar ablation appeared to be distributed uniformly between the electrode and the ground surface, but the electric field in bipolar ablation was focused in the regions between the two electrodes. For bipolar ablation, when the distances between the electrodes were 2 cm and 3 cm, the lesion created was contiguous and covered the areas surrounding both electrodes. However, when the distances between the electrodes were 4 cm and 5 cm, the lesions created were not contiguous and shaped similar to performing two monopolar ablation operations.
Citation
Proceedings of the 3rd IASTED International Conference on Biomedical Engineering 2005, 206-209, 2005
Subjects

Bipolar

Cancer tissue

Finite element

Hepatic

Radio-frequency

Three-dimensional

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback