Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Ultrasonically anchored core–shell Au–Pt nanoparticles on g-C3N4-modified screen-printed carbon electrode for efficient electrochemical detection of diclofenac in aquatic environments
Loading...
Thumbnail Image

Ultrasonically anchored core–shell Au–Pt nanoparticles on g-C3N4-modified screen-printed carbon electrode for efficient electrochemical detection of diclofenac in aquatic environments

Author(s)
Chinnawat, Sirinyakorn
Detsri, Ekarat
Thaipukdee, Piyathida
Pho-ngernngam, Chakkaphan
Jindaphet, Phetradar
Lerdpiriyaskulkij, Natee
Khattiya, Akrarath
Tongpoolsomjit, Kongaphisith
Mathaweesansurn, Arjnarong
Date Issued
April 1, 2026
Type
Article
DOI
10.1016/j.diamond.2026.113494
Abstract
The widespread occurrence of pharmaceutical residues, particularly diclofenac (DCF), in aquatic environments poses serious ecological and health risks due to their persistence and inefficient removal by conventional treatment systems. This study reports a highly sensitive electrochemical sensor based on a core–shell AuPt nanoparticles (Au0-Pt0NPs) decorated graphitic carbon nitride (g-C3N4) heterostructure modified screen-printed carbon electrode (SPCE) for DCF monitoring. The Au0-Pt0NPs/g-C3N4 nanocomposite was prepared using the ultrasonication method, in which ultrasonic energy facilitated hydrogen bonding between the Au0-Pt0NPs and g-C3N4 support. The incorporation of Au0-Pt0NPs onto the g-C3N4 surface provides strong interfacial adhesion, which effectively enhances charge carrier separation and promotes rapid electron transfer across the interface on the SPCE surface during DCF analysis. Optimization of experimental parameter showed that the electrode fabricated at 1.5 mg mL−1nanocomposite concentration, 15 s interval time analysis, a scan rate of 100 mV s−1and PBS buffer at pH 7.0 exhibited the highest peak current. The Au0-Pt0NPs/g-C3N4/SPCE sensor displayed a wide linear range of 0.25–1000 μmol L−1, which LOD of 0.25 μmol L−1, along with excellent reproducibility (%RSD = 1.12%) and stability (%RSD = 0.24%, after storage for 30 day). The electrode demonstrated strong selectivity against interfering species. Validation with aquatic environments samples achieved recoveries of 98.88–103.49%, and ANOVA analysis confirmed no significant difference (p = 0.527 > 0.05) compared with HPLC results (R2 > 0.99). The synergistic effect of Au0-Pt0NPs/g-C3N4 enhanced catalytic performance, making the developed SPCE platform a reliable, and cost-effective sensor for detecting of DCF pollutants.
Citation
Diamond and Related Materials, 164, 2026
Subjects

Aquatic environments

Core-shell Au–Pt nano...

Diclofenac

g-C3N4heterostructure...

Screen-printed carbon...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback