Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Influence of geometric parameters of alternate axis twisted baffles on the local heat transfer distribution and pressure drop in a rectangular channel using a transient liquid crystal technique
Loading...
Thumbnail Image

Influence of geometric parameters of alternate axis twisted baffles on the local heat transfer distribution and pressure drop in a rectangular channel using a transient liquid crystal technique

Author(s)
Phila, Arnut
Thianpong, Chinaruk
Eiamsa-Ard, Smith
Date Issued
January 1, 2019
Type
Article
DOI
10.3390/en12122341
Abstract
This paper reports the effects of alternate axis twisted baffle geometric parameters on the heat transfer and flow characteristics within rectangular channels. In our experiments we used modified shapes of alternate axis twisted baffles according to relative pitch ratios (s/w) equal to 2-12 and twist ratios (y/w) equal to 1-5, under conditions where the angle of attack (a) was 90 and the relative blockage height (e/Dh) was at a constant value of 0.095. The results for the Reynolds numbers based on the duct hydraulic diameter ranged from 9000 to 24,000 at a constant Prandtl number, Pr = 0.707, using air as a working fluid. A 0.05 mm thick stainless-steel foil was used as a heater, and a thermochromic liquid crystal technique was used to obtain the local temperature distribution on the heated surfaces. Images were captured in areas with periodic, fully developed regions in the channel. The results show that rectangular channels equipped with alternate axis twisted baffles demonstrated 80%-185% greater heat transfer than rectangular channels with no baffles. Channels with alternate axis twisted baffles at higher twist ratios (y/w) and smaller relative pitch ratios (s/w) showed increased heat transfer, as well as pressure loss within the system, compared with other types of twisted baffles. The thermal enhancement factor of the rectangular channels equipped with alternate axis twisted baffles was higher than that for transverse baffles and smooth channels under similar operating conditions.
Citation
Energies, 12(12), 2019
Subjects

Alternate axis twiste...

Heat transfer

Pressure loss

Rectangular channel

Thermochromic liquid ...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback