  4. The Application of Polarization and Depolarization Current on the Large Turbo-generators
Loading...
Thumbnail Image

The Application of Polarization and Depolarization Current on the Large Turbo-generators

Author(s)
Jeenmuang, S.
Pannil, P.
Mongkolsatitpong, S.
Trakuldit, S.
Wuti, V.
Pattanadech, N.
Date Issued
January 1, 2022
Type
Conference Paper
DOI
10.23919/CMD54214.2022.9991272
Abstract
This paper represents the application of the polarization and depolarization current (PDC) measurement of the stator winding insulation of two large turbo-generators, which have the same rate of 50.8 MVA, and 11.5 kV. The PDC measurements were conducted on the stator winding insulation of both generators by using two different test circuits i.e., (individual) phase-to-ground insulation and interphase insulation circuits. Then, the PDC results of the two investigated generators were compared. To evaluate the phase-to-ground insulation condition of the stator winding insulation of both generators, the conventional dielectric parameters in the time domain, such as polarization index and insulation resistance, were also studied. Moreover, the PDC results in the time domain were converted into the dielectric dissipation factor in the frequency domain to allow the analyzing the phase-to-ground insulation of the stator winding of the generators. The PDC results of the phase-to-ground insulation circuits of both investigated generators illustrate the bent shape of PDC results which were affected by the influence of the stress control coating resulting in a high value of the Polarization index. Besides, the PDC results of the interphase insulation circuits of the first investigated generator illustrate the polarity reversal (or Anomalous current) of both PDC, while the second investigated generator illustrates the non-polarity reversal of both PDC. The polarity reversal of the PDC results of the interphase insulation was due to the dielectric loss of the interphase insulation is a lower influence when compared with that of phase-to-ground insulation.
Citation
2022 9th International Conference on Condition Monitoring and Diagnosis Cmd 2022, 118-121, 2022
Subjects

dielectric dissipatio...

PDC

polarization index

stator winding

turbo-generator

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback