  4. Thermal performance evaluation of a channel with twisted baffles installed: Effect of twisted baffle arrangement
Loading...
Thumbnail Image

Thermal performance evaluation of a channel with twisted baffles installed: Effect of twisted baffle arrangement

Author(s)
Eiamsa-ard, S.
Pingta, S.
Phila, A.
Woncharee, K.
Chamoli, S.
Thianpong, C.
Date Issued
March 1, 2026
Type
Article
DOI
10.1016/j.icheatmasstransfer.2025.110430
Abstract
This research aims to introduce newly designed twisted baffle for enhancing heat transfer in solar air heater. This study examined the thermo-hydraulic performance of converging twisted baffles (C-TBs) and diverging twisted baffles (D-TBs) with different numbers of loops (n = 2, 4, 6, and 8) over a Reynolds number range (Re) of 6000–24,000. The results demonstrated that both converging twisted baffles and diverging twisted baffles significantly enhanced heat transfer compared to a smooth channel. The Nusselt number, friction factor, and thermal performance factor (TPF) increased as the number of loops decreased, attributed to stronger flow reattachment. Specifically, twisted baffles with 2, 4, 6, and 8 loops enhanced Nu by approximately 2.29–3.43, 2.02–3.05, 1.77–2.74, and 1.61–2.48 times, respectively, while the friction factor increased by 5.19–5.71, 4.61–5.01, 4.06–4.43, and 3.73–4.06 times, respectively. For a given number of loops, diverging twisted baffles consistently provided higher heat transfer enhancement than converging twisted baffles, albeit with slightly increased friction losses. Across the investigated range, the 2-loop diverging twisted baffles exhibited the best overall performance, achieving the highest Nusselt number ratio (Nu/NuSC where NuSC is the Nusselt number of the smooth channel) of 3.43 and a maximum thermal performance factor of 1.92 at Reynolds number of 6000, establishing it as the optimal configuration among those tested. This research contributes valuable design guidelines for selecting optimal baffle configurations, thereby supporting the development of more energy-efficient solar thermal systems.
Citation
International Communications in Heat and Mass Transfer, 172, 2026
Subjects

Heat exchanger

Heat transfer enhance...

Solar air heater

Thermal performance

Twisted baffle

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback