  4. Performance analysis of non‐interferometry based surface plasmon resonance microscopes
Loading...
Thumbnail Image

Performance analysis of non‐interferometry based surface plasmon resonance microscopes

Author(s)
Tontarawongsa, Sorawit
Visitsattapongse, Sarinporn
Pechprasarn, Suejit
Date Issued
August 1, 2021
Type
Article
DOI
10.3390/s21155230
Abstract
Surface plasmon microscopy has been of interest to the science and engineering commu-nity and has been utilized in broad aspects of applications and studies, including biochemical sensing and biomolecular binding kinetics. The benefits of surface plasmon microscopy include label‐free detec-tion, high sensitivity, and quantitative measurements. Here, a theoretical framework to analyze and com-pare several non‐interferometric surface plasmon microscopes is proposed. The scope of the study is to (1) identify the strengths and weaknesses in each surface plasmon microscopes reported in the literature; (2) quantify their performance in terms of spatial imaging resolution, imaging contrast, sensitivity, and measurement accuracy for quantitative and non‐quantitative imaging modes of the microscopes. Six types of non‐interferometric microscopes were included in this study: annulus aperture scanning, half annulus aperture scanning, single‐point scanning, double‐point scanning, single‐point scanning, at 45 degrees azimuthal angle, and double‐point scanning at 45 degrees azimuthal angle. For non‐quantitative imaging, there is a substantial tradeoff between the image contrast and the spatial resolution. For the quantitative imaging, the half annulus aperture provided the highest sensitivity of 127.058 rad/μm2 RIU−1, followed by the full annulus aperture of 126.318 rad/μm2 RIU−1. There is a clear tradeoff between spatial resolution and sensitivity. The annulus aperture and half annulus aperture had an optimal resolution, sensitivity, and crosstalk compared to the other non‐interferometric surface plasmon resonance micro-scopes. The resolution depends strongly on the propagation length of the surface plasmons rather than the numerical aperture of the objective lens. For imaging and sensing purposes, the recommended mi-crofluidic channel size and protein stamping size for surface plasmon resonance experiments is at least 25 μm for accurate plasmonic measurements.
Citation
Sensors, 21(15), 2021
Subjects

Instrumentation

Quantitative measurem...

Surface plasmon micro...

Surface plasmon reson...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback