  4. An experimental study of natural lighting for energy conservation using top-up control method
Loading...
Thumbnail Image

An experimental study of natural lighting for energy conservation using top-up control method

Author(s)
Wangkadilok, Chaichana
Sriratana, Witsarut
Tammarugwattana, Narin
Tanachaikhan, Lerdlekha
Date Issued
December 1, 2008
Type
Conference Paper
DOI
10.1109/SICE.2008.4655028
Abstract
This paper presents the experiment-based analysis of interior illuminance from natural lighting through clear glazed window of a reference room located in Bangkok, Thailand, during February to May 2007 as a case study. The point illuminances measured by photoconductive sensors were collected every 5 minutes and the average interior illuminance from natural lighting were then calculated instantaneously. In this study, natural lighting also aims to reduce the requirement of electric lighting during daytime (7 am-5 pm) of the reference room. If natural lighting alone cannot supply the light at the required value, the electric lighting is assumed to be switched on under top-up control method to maintain the standard illuminance level. The average interior illuminance, which comprises of natural light and electric light, is controlled to be stable at the IES standard level of 500 lux. Nine sets of high performance lamp, 56 lm/W of efficacy, are assumed to supply the light to meet the standard condition. The requirements of supplementary lighting and possible savings during the test months are finally estimated. © 2008 SICE.
Citation
Proceedings of the SICE Annual Conference, 2196-2199, 2008
Subjects

Electric lighting

Illuminance

LDR

Natural lighting

Top-up control

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback