Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Heat transfer augmentation in a helical-ribbed tube with double twisted tape inserts
Loading...
Thumbnail Image

Heat transfer augmentation in a helical-ribbed tube with double twisted tape inserts

Author(s)
Promvonge, Pongjet
Pethkool, Somsak
Pimsarn, Monsak
Thianpong, Chinaruk
Date Issued
August 1, 2012
Type
Article
DOI
10.1016/j.icheatmasstransfer.2012.05.015
Abstract
Turbulent convective heat transfer characteristics in a helical-ribbed tube fitted with twin twisted tapes have been investigated experimentally. The experiment was carried out in a double tube heat exchanger using the helical-ribbed tube having a single rib-height to tube-diameter ratio, e/D H=0.06 and rib-pitch to diameter ratio, P/D H=0.27 as the tested section. The insertion of the double twisted tapes with twist ratio, Y, in the range of 2.17 to 9.39 is to create vortex flows inside the tube. The inserted ribbed tube is arranged in similar directions of the helical swirl of the twisted tape and the helical rib motion of the tube (called co-swirl). Effects of the co-swirl motion of the ribbed tube and the double twisted tapes with various twist ratios on heat transfer and friction characteristics are examined. The results obtained from the ribbed tube and the twin twisted tape insert are compared with those from the smooth tube and the ribbed tube acting alone. The experimental results reveal that the co-swirling inserted tube performs much better than the ribbed/smooth tube alone at a similar operating condition. The co-swirl tube at Y≈8 yields the highest thermal performance at lower Reynolds number (Re). In addition, the correlations of Nusselt number and friction factor as functions of Re, Pr and Y are also proposed. © 2012 Elsevier Ltd.
Citation
International Communications in Heat and Mass Transfer, 39(7), 953-959, 2012
Subjects

Compound heat transfe...

Friction factor

Helical-ribbed tube

Swirl flow

Twisted tape

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback