Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Mechanical compliance of the endocardium
Loading...
Thumbnail Image

Mechanical compliance of the endocardium

Author(s)
Bin Choy, Young
Cao, Hong
Tungjitkusolmun, Supan
Tsai, Jang Zern
Haemmerich, Dieter
Vorperian, Vicken R.
Webster, John G.
Date Issued
December 1, 2002
Type
Article
DOI
10.1016/S0021-9290(02)00228-2
Abstract
Radio-frequency (RF) ablation is an accepted treatment for cardiac arrhythmias related to abnormal focal cardiac substrate. The penetration depth of the electrode into the endocardium affects lesion size, a critical determinant of success of RF ablation. We measured the relation between the mechanical compliance and the penetration depth of RF ablation catheter electrode at frequently ablated areas of the endocardium and examined the influence of time after death on mechanical properties of the tissue. We measured force versus time for eight insertion depths of the catheter electrode into full-thickness endocardial samples derived from the mitral valve annulus, the left ventricular free wall and the tricuspid valve annulus. We varied the time after death at 15, 40min, 3, 8, and 18h and repeated our measurements. At 15min after death, the first 0.5mm penetration depth caused the fastest relaxation at 55s. Force decay decreased dramatically at 15min after death as the penetration depth increased from 0.5 to 4mm. We used the force data sampled at 60s after insertion to approximate the elasticity. We observed the relations between the force versus the insertion depth. The force increased by a factor of 5 for the mitral valve annulus and 8 for the left free wall from 15min to 18h. We derived coefficients of a second-order polynomial equation relating the force data to insertion depth with R2>0.99. © 2002 Elsevier Science Ltd. All rights reserved.
Citation
Journal of Biomechanics, 35(12), 1671-1676, 2002
Subjects

Elastic component

Insertion depth

Relaxation effect

RF ablation

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback