A partial discharge testing system based on a 5-level converter with different control signals

Author(s)
Yomkaew, N.
Marukatat, N.
Yutthagowith, P.
Date Issued
November 1, 2018
Type
Conference Paper
DOI
10.1109/AUPEC.2018.8758027
Abstract
In this paper, analyses of a partial discharge (PD) testing systems using a voltage source from a 5-level converter with different control signals are presented. The low voltage source with 200 Hz of the test system is generated using the 5-level converter. The converter connected to a high voltage transformer, a partial discharge detection. The LC-filter type is set for the test system. The efficiency of voltage source from the 5-level converter with different control signal topologies, i.e. 5-level square wave, 5-level quasi-square wave, and 5-level sinusoidal pulse width modulation (SPWM) with modulation index (ma) of 1.0. The effect of the topologies to partial discharge test system is presented and compared in cases of the voltage difference, total harmonic distortion (THDv) of the output voltage, and the background noises in the partial discharge testing system with no-load and load test with a potential transformer (PT). It is found that the 5-level sinusoidal pulse width modulation (SPWM) with modulation index 1.0 provides the best performance in cases of the voltage difference and THDv of below 5%, and the background noise of below 2.5 pC.
Citation
Australasian Universities Power Engineering Conference Aupec 2018, 2018
Subjects

5-level converter

partial discharge

quasi-square wave

sinusoidal pulse widt...

square wave

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback