Repository logo
Communities & Collections
Research Outputs
Fundings & Projects
People
Statistics
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. KMITL
  3. Publication
  4. Microwave ablation system design to study the effects of coaxial antenna on in-vitro animal tissue
Loading...
Thumbnail Image

Microwave ablation system design to study the effects of coaxial antenna on in-vitro animal tissue

Author(s)
Chaichanyut, M.
Lertprasert, P.
Tungjitkusolmun, S.
Date Issued
January 1, 2014
Type
Conference Paper
DOI
10.1007/978-3-319-02913-9_160
Abstract
This paper presents a novel low cost microwave ablation system design to study the effects of coaxial antenna on In Vitro animal tissues. The system utilizes a high-voltage power supply so that the magnetron can generate a microwave field continuously, and its output power can be adjusted from 10 - 80 W at frequency of 2.45GHz. We control output microwave power level by using control the magnetron power supply, which it is an important part of a microwave heating system. Power control of the magnetron’s power supply is desired for microwave heating to enhance performance and to provide system flexibility. The high frequency switching technique in the power supply control is costly and complicated. In another way, pulsing the output power of the magnetron can be simply realized with TRIAC, but in that case the magnetron does not operate continuously. The proposed circuit is a simple one with TRIAC. The power control is achieved by controlling the triggering events at appropriate phase angle of the household 220V. Experimental protocol was composed by a radiation system and a thermometry system. Coaxial antenna works at 2.45 GHz, power apply during experiments was 10W×8min; 20W×4min; 40W×2min and 80W×1min. Thermal sensors were placed next to the antenna at 1mm., a large number of experiments on porcine liver are carried out, the temperature distribution within the liver are measured and illustrated, for cases of different injected microwave power and ablation time. In addition, the ablation areas in cases of different input microwave powers are measured also. All these results indicate the potential validity of this system on medical treatment of liver cancer of human body.
Citation
Ifmbe Proceedings, 43, 629-632, 2014
Subjects

Animal tissue

Coaxial antenna

In Vitro

Microwave ablation

Microwave heating

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science