The Analysis of Lightning Strikes to MEA's Distribution Lines on Different Impact Positions

Author(s)
Sestasombut, P.
Ngaopitakkul, A.
Date Issued
January 1, 2017
Type
Conference Paper
DOI
10.1016/j.egypro.2017.11.067
Abstract
This paper focuses on behaviour of voltage across insulator when the lightning strikes on different impact positions of Metropolitan Electricity Authority (MEA) 24 kV distribution lines in Thailand. The simulations and analysis are performed using Alternative Transients Program/Electromagnetic Transients Program (ATP/EMTP) to investigate the voltage across insulator. The results indicate that when the lightning strikes to phase conductor or shielding failure occurs, the voltage across insulator where the terminal point is more than the middle point is about 1.5 times. This case, the ground resistance and grounding distance of overhead ground wire (OHGW) is not influential on the voltage across insulator. However, in case the lightning strikes to OHGW, the voltage across insulator where the terminal point is more than the middle point is about 1.2 times and the ground resistance as well as grounding distance of OHGW plays an important role for the voltage across insulator. The analysis shows that when the lightning strikes to the terminal line are considerably more severe than the middle line. Therefore, the lightning protection should be specially considered at the terminal point. The peak current magnitude and the front time lightning current waveform are essential parameters when observing the voltage across insulator. However, the tail time is not an important parameter with regard to the voltage across insulator.
Citation
Energy Procedia, 141, 507-511, 2017
Subjects

ATP/EMTP

lightning strikes

middle

terminal

voltage across insula...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback