    Classification of Capacitor Bank Switching Using Fuzzy Interference Systems in 230 kV Substation
    (2024-01-01)
    Patcharoen, Theerasak
    ;
    ; ; ;
    Lertwanitrot, Praikanok
    Flexible AC transmission systems are used for enhancing the stability, transmission efficiency, and reliability of AC grids. Additionally, the most cost-effective devices for compensating reactive power are Mechanically Switched Capacitors (MSCs). This study proposes a novel algorithm for detection and capacitor bank switching transient signals in MSC, to prevent the protective relay maloperation by these transients. The Discrete wavelet transform (DWT) is used for effective time-frequency analysis and detection of measured three-phase current signals. DWT extracts the detailed wavelet coefficients of current signals at levels 1 to 30. In addition, the fuzzy inference system (FIS) has been used to determine the type of switching transient. The proposed combination of FIS and DWT has been tested on 230 kV substation and the result demonstrated precision for the identification and classification of both transient signals in MSC with 88% accuracy rate.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    SOH- and Temperature-Aware Adaptive SOC Boundaries for Second-Life Li-Ion Batteries in Off-Grid PV–BESSs
    (2026-02-01)
    Wang, Hongyan
    ;
    ;
    In this study, an adaptive state-of-charge (SOC) boundary strategy (ASBS) is proposed that dynamically adjusts the admissible upper and lower SOC limits of second-life lithium-ion batteries in off-grid photovoltaic battery energy storage systems (PV-BESSs) based on real-time state of health (SOH) and temperature feedback. The strategy is formulated using a unified electrical–thermal–aging model with an online state estimator and ensures both electrical safety and power feasibility while remaining fully compatible with standard energy management functions. Two representative simulations—a single-day operating profile and a continuous thirty-day sequence—demonstrate the effectiveness of the ASBS. In the twenty-four-hour case, the duration spent in high state-of-charge conditions is reduced by approximately 0.30–0.50 h, the abrupt end-of-charging transition is eliminated, and the temperature rise is slightly moderated, all without any loss of energy supply. Over thirty days, the difference between the ASBS and a fixed state-of-charge window remains effectively zero for almost all hours, with only a brief midday deviation of −4 to −5 percentage points and no cumulative drift. Indicators of electrical and thermal stress improve substantially, including an approximate 70% reduction in the root mean square charging current. These results confirm that the ASBS provides a practical and non-intrusive means of mitigating stress on second-life lithium-ion batteries while preserving full energy autonomy in off-grid photovoltaic systems.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    A new directional relay algorithm for the protection of transmission network systems using discrete wavelet transforms
    This paper proposes a novel directional relay algorithm to protect transmission network systems with an application of discrete wavelet transform (DWT). The fault signals are simulated using PSCAD/EMTDC. The coefficients of the positive sequence current obtained from each bus are compared in order to identify the direction of fault signals. The coefficient ratio between buses that the fault occurred is calculated so that the proper protective relay sequence can be selected. The result is shown that the algorithm is capable of performing the fault detection as well as arranging the protective relay sequence, with accurate results. ©2010 IEEE.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Comparison of artificial intelligence methods for fault classification of the 115-kv hybrid transmission system
    (2020-06-01)
    Klomjit, Jittiphong
    ;
    This research proposes a comparison study on different artificial intelligence (AI) methods for classifying faults in hybrid transmission line systems. The 115-kV hybrid transmission line in the Provincial Electricity Authority (PEA-Thailand) system, which is a single circuit single conductor transmission line, is studied. Fault signals in the transmission line were generated by the EMTP/ATPDraw software. Various factors such as fault location, type, and angle were considered. Then, fault signals were analyzed by coefficient details on the first scale of the discrete wavelet transform. Daubechies mother wavelet from MATLAB software was used to decompose the fault signal. The coefficient value of the mother wavelet behaved depending on the position, inception of fault angle, and fault type. AI methods including probabilistic neural networks (PNNs), back-propagation neural networks (BPNNs), and support vector machine (SVM) were used to identify faults. AI input used the maximum first peak coefficients of phase ABC and zero sequence. The results obtained from the study were found to be satisfactory with all AI methodologies having an average accuracy of more than 98% in the case study. However, the SVM technique can provide more accurate results than the PNN and BPNN techniques with less computation burden. Thus, it is suitable for being applied to actual protection systems.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Effects of Conditional Changes on High-Voltage Direct Current Transmission Line Characteristic
    (2022-01-01) ; ;
    Leelajindakrairerk, Monthon
    ;
    Phannil, Natthanon
    ;
    Bunjongjit, Sulee
    The high-voltage direct current (HVDC) transmission system, which links the Gurun Substation of the National Electric Authority of Malaysia (Tenaga Nasional Berhad, TNB) with the Khlong Ngae Station of the Electricity Generating Authority of Thailand (EGAT), has been extensively researched to achieve the highest quality because it is the largest of its kind in Thailand, and there is a plant to expand its transmission power. However, the impact on the whole system is under-researched. To study and develop this system, the HVDC transmission line is modelled with the MATLAB/Simulink program and a laboratory setup to investigate the effect of transmission line distance, load power, and voltage on power loss, voltage drop, and waveform. The HVDC transmission line parameters are calculated from the actual transmission line parameters and converted to the simulation model parameters using the per-unit method. The model is verified and tested by the simulation program before creating the experimental setup. The simulation and experimental results demonstrate the effects of changing system conditions via the three aspects. All the three conditions directly affect the HVDC transmission line; nevertheless, they affect each aspect differently.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    A phase diagram approach to the detection and location of faulty capacitor units in A 115-kV capacitor bank based on unbalanced current arguments
    (2023-03-01) ;
    Lertwanitrot, Praikanok
    ;
    The protection of traditional high voltage capacitor banks relies on an unbalance relay which operates when an internal fuse is blown. However, the unbalance relay cannot indicate cause or position of the fault. Thus, an operator wastes time and human resources investigating the fault issues. To address this issue, a method to locate the fault position in a capacitor bank is developed in this study. The study was simulated by using PSCAD software and modeled on the 115-kV system of the Electricity Generating Authority of Thailand (EGAT). Case studies involving faults with varied phases, side and branch connections, row connections, and inception angles were considered. Moreover, the magnitude and argument of the current phase and unbalanced current were analyzed to identify the fault location in a capacitor bank. The performance of the proposed method was verified via comparison with that of traditional methods and the results of laboratory experiments. In addition, various voltage systems were observed to verify the flexibility and accuracy of the proposed method. The results demonstrate that the proposed method was more efficient than traditional methods at locating the fault position in a capacitor bank.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Lightning location on 115-kV transmission line using travelling waves
    (2018-11-01)
    Bunjongjit, Sulee
    ;
    ;
    Leelajindakrairerk, Monthon
    A lightning strike can be very severe to the transmission system with high impulse current that can damage equipment and cause the operation of the system to be halted. However, currently used lightning location methodology that does not provide the desired accuracy. So, this paper proposed the lightning location methodology on the transmission line based on discrete wavelet transform (DWT) and travelling wave theory. The Alternative Transients Program/Electromagnetic Transients Program (ATP/EMTP) software has been used to simulate the transmission system using in this research. The comparative study between proposed and currently used has been done in order to evaluate the performance in term of accuracy to detect the lightning location on the transmission line. The result has shown that the proposed methodology can be achieved desire accuracy and can be further implemented in actual transmission line protection system in the future.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Analysis of Investment Feasibility for EV Charging Stations in Residential Buildings
    (2025-09-01)
    Chiradeja, Pathomthat
    ;
    ;
    Sottiyaphai, Chayanut
    ;
    ;
    Klomjit, Jittiphong
    This study investigates the financial and operational feasibility of deploying electric vehicle (EV) charging infrastructure within high-density residential buildings, utilizing empirical operational data combined with comprehensive financial modeling. A 14-day monitoring period conducted at a residential complex comprising 958 units revealed distinct charging behaviors, with demand peaking during weekday evenings between 19:00 and 22:00 and displaying more dispersed yet lower overall utilization during weekends. Energy efficiency emerged as a significant operational constraint, as standby power consumption contributed substantially to total energy losses. Specifically, while total energy consumption reached 248.342 kW, only 138.24 kW were directly delivered to users, underscoring the necessity for energy-efficient hardware and intelligent load management systems to minimize idle consumption. The financial analysis identified pricing as the most critical determinant of project viability. Under current cost structures, financial break-even was attainable only at a profit margin of 0.2286 USD (8 THB) per kWh, while lower margins resulted in persistent financial deficits. Sensitivity analysis further demonstrated the considerable vulnerability of the project’s financial performance to small fluctuations in profit share and utilization rate. A 10% reduction in either parameter entirely eliminated the project’s ability to reach payback, while variations in energy costs, capital expenditures (CAPEX), and operational expenditures (OPEX) exerted comparatively limited influence. These findings emphasize the importance of precise demand forecasting, adaptive pricing strategies, and proactive government intervention to mitigate financial risks associated with residential EV charging deployment. Policy measures such as capital subsidies, technical regulations, and transparent pricing frameworks are essential to incentivize private sector investment and support sustainable expansion of EV infrastructure in residential sectors.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Behaviour analysis of H-bridge high-voltage capacitor banks fault on 230-kV substation using discrete wavelet transform
    (2023-11-01)
    Chiradeja, Pathomthat
    ;
    Lertwanitrot, Praikanok
    ;
    ;
    The protection of traditional high-voltage capacitor banks relies on an unbalance relay which operates when an internal fuse is blown. However, the unbalance relay cannot indicate the cause of the fault. Thus, an operator wastes time and human resources investigating the fault issues. In this paper, a fault which occurred in a 230-kV power system of Electricity Generating Authority of Thailand was observed by performing simulations using the Power Systems Computer Aided Design (PSCAD) program. The study system based on the double bus station and 72 MVAR capacitor banks was installed in the form of a back-to-back topology. Three scenarios were considered: normal condition, fault occurrence in one capacitor bank and fault occurrence in both capacitor banks. Current characteristics such as the current phase and difference in unbalance current were considered. In addition, discrete wavelet transform was applied to solve the ambiguity of current generated from the PSCAD. The authors’ results suggest that identifying fault events using a coefficient of wavelet is more efficient than relying on the current amplitude. The findings mentioned in this paper can be applied in a traditional power system protection scheme to enhance a system's reliability.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Discrete wavelet transform and probabilistic neural network algorithm for classification of fault type in underground cable
    (2012-01-01) ;
    Suttisinthong, N.
    This paper proposes an algorithm based on a combination of discrete wavelet transform (DWT) and probabilistic neural network (PNN) for classifying fault types on underground cable. Simulations and the training process for the PNN are performed using ATPIEMTP and MATLAB. The mother wavelet daubechies4 (db4) is employed to decompose high frequency component from these signals. The maximum coefficients of DWT of phase A, B, C and zero sequence for post-fault current waveforms are used as an input for the training pattern. Various cases studies based on Thailand electricity distribution underground systems have been investigated so that the algorithm can be implemented. The coefficients of DWT are also compared with those of PNN in this paper. The results show that the proposed algorithm is capable of performing the fault classification with satisfactory accuracy. © 2012 IEEE.