  4. Integrated Assessment of Rooftop Photovoltaic Systems and Carbon Footprint for Organization: A Case Study of an Educational Facility in Thailand
Loading...
Thumbnail Image

Integrated Assessment of Rooftop Photovoltaic Systems and Carbon Footprint for Organization: A Case Study of an Educational Facility in Thailand

Author(s)
Leeabai, Nattapon
Sakaraphantip, Natthakarn
Kunbuala, Neeraphat
Roongrueng, Kamonchanok
Nukunudompanich, Methawee
Date Issued
May 1, 2025
Type
Article
DOI
10.3390/en18102485
Abstract
This study presents an integrated methodology to assess and reduce greenhouse gas (GHG) emissions in institutional buildings by combining organizational carbon footprint (CFO) analysis with rooftop photovoltaic (PV) system simulation. The HM Building at King Mongkut’s Institute of Technology Ladkrabang (KMITL), Thailand, was selected as a case study to evaluate carbon emissions and the feasibility of solar-based mitigation strategies. The CFO assessment, conducted in accordance with ISO 14064-1:2018 and the Thailand Greenhouse Gas Management Organization (TGO) guidelines, identified total emissions of 1841.04 tCO2e/year, with Scope 2 electricity-related emissions accounting for 442.00 tCO2e/year. Appliance-level audits revealed that classroom activities represent 36.7% of the building’s electricity demand. These findings were validated using utility data totaling 850,000 kWh/year. A rooftop PV system with a capacity of 207 kWp was simulated using PVsyst software (version 7.1), incorporating site-specific solar irradiance and technical loss parameters. Monocrystalline modules produced the highest energy output of 292,000 kWh/year, capable of offsetting 151.84 tCO2e/year, equivalent to 34.4% of Scope 2 emissions. Economic evaluation indicated a 7.4-year payback period, with a net present value (NPV) of THB 12.49 million and an internal rate of return (IRR) of 12.79%. The integration of verified CFO data with empirical load modeling and derated PV performance projections provides a robust, scalable framework for institutional carbon mitigation. This approach supports data-driven Net Zero campus planning aligned with Thailand’s Nationally Determined Contributions (NDCs) and carbon neutrality policies.
Citation
Energies, 18(10), 2025
Subjects

carbon footprint for ...

PVsyst

rooftop photovoltaic

techno-economic analy...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback