Entropy generation and thermal performance of tubular heat exchanger fitted with louvered corner-curved V-baffles

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Abstract

The current article deals with an experimental study on entropy generation analysis and thermohydraulic performance of a uniform heat-flux tube equipped with louvered corner-curved baffle tape (LCBT). Air was drawn into the inserted tube for the Reynolds number (Re) between 4760 and 29,300. The V-shaped LCBT arranged by V-tip in downstream direction was introduced with three baffle pitch ratios (PR = 1–2) and six louver angles (θ = 0–90°) for a fixed attack angle (α) of 30° and baffle height ratio (BR = 0.25). The impacts of investigated parameters on the thermal enhancement factor (TEF), Nusselt number (Nu), friction factor (f), and total entropy generation (S˙gen) were examined. The measurements showed that the LCBT with the smallest values of PR = 1, θ = 0° give the largest Nu and f at about 4.4 and 19.2 times above the plain tube values, respectively. However, the greatest TEF around 2.23 was seen for employing the LCBT at PR = 1, θ = 45°. The entropy analysis also showed that the S˙gen is found to decline with the increment of PR and θ, whereas the minimal S˙genis at PR = 1, θ = 0° for lower Re but at PR = 1, θ = 45° for higher Re. Furthermore, the Nu and f empirical correlations for employing LCBTs were also proposed.

Description

Keywords

Entropy generation, Heat exchanger, Louvered baffle, Thermohydraulic performance, Vortex generator

Citation

International Journal of Heat and Mass Transfer, 201, 2023

Collections

Endorsement

Review

Supplemented By

Referenced By