Publication:
Stator faults detection based on the dq0 voltage components

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Research Projects

Organizational Units

Journal Issue

Abstract

This paper presents the technique for detection of shorted turns in stator winding of induction motors. The strategy is based on the dq0 voltage components. The proposed technique determines dq components of time domain of harmonics obtained from Park transformation instead of the stator phase voltage. Zero component (0) is calculated from the fundamental voltage excitation only. In the testing, the supply is sinusoidal waveform and the motor must be star connected with floating neutral. From experimental results, pattern of dq0 voltage components in order to use for the stator faults detection is possible. ©2008 IEEE.

Description

Keywords

Condition monitoring, Dq0 components, Fault detection, Induction motor, Stator fault

Citation

Proceedings of the IEEE International Conference on Industrial Technology, 2008