Publication: Investigation on the performance between standard and high efficiency induction machines operating as self-excited induction generators feeding the non-linear loads
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
This paper proposes the investigation on the performance between standard and high efficiency induction machines operating as SEIG feeding the nonlinear loads having same rating of 3 phase, 2.2 kW, 220/380 V, 4 poles. Consideration of capacitance for the SEIG based on equivalent circuit model under steady-state load conditions and a power flow diagram is given. The interpretation of experimental results can be guidelines for effective design and development of SEIG with DC supply for wind energy applications. © 2008 IEEE.
Description
Keywords
Energy storage system, Induction machines, Self-excited induction generator
Citation