Ground glass opacity (GGO) nodules detection from lung CT scans
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Ground glass opacity (GGO) nodules have a higher possibility of malignancy compared to other types of nodules appeared in the lung cancer. They are very effortful to detect due to their hazy structures and unclear margins. 65% of lung cancers are missed by the radiologists with the faint appearance of the GGO. Consequently, the detection of GGO is a critical issue and a striving task for the radiologists. This research proposes an automatic detection of GGO remained after the detection of solid opacity. Simple thresholding based on grey levels and mathematical image subtraction are applied for segmentation. Possible false after segmentation are reduced by the support vector machine (SVM). In total 37 GGOs, only 2 are missed by proposed segmentation and the false reduction performance is 94%.