Publication: A logarithmic level-crossing ADC
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
A 3-bit logarithmic level-crossing analog-to-digital converter (LC-ADC) for biomedical applications is presented. Based on the feedback LC-ADC structure, the proposed circuit is realized by using logarithmic charge-scaling digital-to-analog converters. The circuit is designed and simulated with process parameters from a 0.35-μm CMOS technology and a 1.5-V power supply voltage. Process corner simulation results showed that the INL and DNL errors are within the range of +0.14/-0.09LSB and +0.14/-0.21LSB, respectively.
Description
Keywords
analog-to-digital converter (ADC), level-crossing ADC, logarithmic ADC
Citation