Applications of a high frequency current transformer and air-core inductive devices for detecting a partial discharge location in a cable

Author(s)
Paophan, Busayapol
Yutthagowith, Peerawut
Kunakorn, Anantawat
Date Issued
January 1, 2020
Type
Conference Paper
DOI
10.1049/cp.2020.0108
Abstract
This paper presents applications of partial discharge sensing devices for detecting a partial discharge location in a cable. Three devices are under investigated. The first type is a high frequency current transformer (HFCT), while other two types are air core inductive devices with different configuration. The high frequency current transformer is constructed from a ferromagnetic material core, and the winding conductor is in a single compensation form. The first air core inductive device is wound in a single compensation pattern, and uses the return winding in the form of a copper sheet. The second air core inductive device, differently, is in a counter wound compensation pattern. In experiments, a partial discharge sensing device is installed at one end of the cable. The standard pulse calibrator is employed to inject partial discharge pulses at the designated locations along the cable. The Time Domain Reflectometry technique (TDR), which is based on the travelling wave theory, is employed in calculating the partial discharge locations. It is found that these three current transducers can detect the partial discharge pulses, and with the algorithm, which is developed using the Time Domain Reflectometry, the partial discharge location along the cable can be identified accurately.
Citation
Iet Conference Publications, 2020(CP771), 2020
Subjects

Air-core inductive de...

High frequency curren...

Partial discharge loc...

Time domain reflectom...

Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback